Pfaff EcoDrive P40 ED Instruction Manual page 52

Hide thumbs Also See for EcoDrive P40 ED:
Table of Contents

Advertisement

Input
* = These parameters remain unchanged when the set parameter values are reset,
52
7
725
Control panel display
ON = actual speed
OFF = remaining stitches for bobbin
thread
726
Counter for bobbin monitoring
727
Counter for bobbin monitoring effective-
ON = stop and signal on output
OFF = signal on output without stop
729
Start delay after lowering presser
foot [ms]
730
Lift delay for presser foot at end of
seam
747
Operating mode for thread clamp
ON = pneumatic, OFF = electric
760
Remaining no. of stitches after reaction
of bobbin thread monitor during bobbin
thread monitoring
1 = Multiplying factor for fi xed
value x 10 during direct monitoring
2 = Multiplying factor for fi xed
value x 200 during indirect
monitoring
761
Extension thread tension release /
thread pulling [ms]
769
Remaining number of stitches for
stitch counter(indirect bobbin thread
monitoring)
770
Lifting delay for presser foot when
pedal position is "-1" [ms]
772
Operating mode trimming
ON = with shortened trim stitch trim-
ming always with short stitch length
(parameter 988 = ON)
OFF = standard trimming
see Chapter 10.01 Reset / Cold start.
1, 2, 3
B
ON - OFF
1, 2, 3
B
ON - OFF
1, 2, 3
B
ON - OFF
1, 2, 3
B
10 - 2550
1, 2, 3
B
0 - 2000
1, 2, 3
B
ON - OFF
1, 2, 3
A
0 - 250
1, 2, 3
B
0 - 3000
1, 2, 3
B
1 - 2550
1, 2
B
10 - 2550
3
B
10 - 2550
1, 2, 3
B
ON - OFF
P70 ED
ON
OFF
OFF
140
50
OFF
10
0
100
50
100
OFF