IMAGO VisionBox AGE-X5 Hardware Manual page 28

Hide thumbs Also See for VisionBox AGE-X5:
Table of Contents

Advertisement

5 Interfaces
Example 1: Connecting multiple cameras to a single output with high-current option.
VisionBox
Digital
Outputs
+ / VCC
OUT 0
OUT 1
OUT 7
Depending on the voltage and isolation requirements of the application, the VisionBox can be
powered from the same or from a different power supply.
Example 2: Connecting a relay to an output with high-current option.
VisionBox
Please note that a flyback diode as shown in the drawing should be used to protect the output
circuit from voltage spikes at deactivation.
Strassheimer Str. 45; 61169 Friedberg - Germany; Tel. +49 6031-6842611; Fax +49 6031-6842612
Camera A
Power VCC
Trigger IN
GND
Camera B
Power VCC
Trigger IN
GND
Camera C
Power VCC
Trigger IN
GND
Figure 18: Digital I/O example 1
Digital
Outputs
+ / VCC
OUT 0
OUT 1
OUT 7
Figure 19: Digital I/O example 2
IMAGO Technologies GmbH
info@imago-technologies.com; www.imago-technologies.com
Page 28 / 36