5 Interfaces
The connector arrangement is shown below:
Figure 17: Digital I/O connectors
External plug component: Phoenix contact MC 1,5/18-STF-3,5 (order no. 1847288)
The standard version of the digital output interface allows high-speed signaling, but with limited
current ability. The output current can be increased by connecting multiple output terminals with
each other. Software must configure the Real-Time Communication Controller to use the same
signal source for these outputs.
A high-current hardware option for the digital outputs is also available. See section 3.2 Operating
Conditions for electrical specifications.
Strassheimer Str. 45; 61169 Friedberg - Germany; Tel. +49 6031-6842611; Fax +49 6031-6842612
IMAGO Technologies GmbH
info@imago-technologies.com; www.imago-technologies.com
Pin
Function
+
Common VCC of outputs
-
Common GND of inputs
IN
Input 0...7
0...7
OUT
Output 0...7
0...7
Table 13: Pin assignment I/O connector