4 Power Connector and LEDs
4 Power Connector and LEDs
4.1 Power Connector
Figure 5: Power plug
The RST terminal can be pulled to GND to reset the VisionBox during operation. A falling edge
will trigger the reset. Leaving the signal floating is the default mode for normal operation.
Phoenix Contact plug component: MC 1,5/4-STF-3,5 (order no. 1847071)
4.2 System LEDs
The computer has four main system LEDs. These LEDs are dual color (bicolor) types. The function-
ality of the LED A, B and C can be changed by software.
Figure 6: Status LEDs
Strassheimer Str. 45; 61169 Friedberg - Germany; Tel. +49 6031-6842611; Fax +49 6031-6842612
LED
Green
Red
On
Orange
blinking
Orange
Green
A
Red
Green
B
Red
Green
C
Red
IMAGO Technologies GmbH
info@imago-technologies.com; www.imago-technologies.com
Pin
Function
+24V
24 V power supply
RST
Reset input, low active
GND
Ground
PE
Shield / housing connection
Table 4: Power connector
Color
Function (green)
Power On
FPGA configuration error
Backup firmware is loaded
System shutdown or reset
User LED 0
User LED 1
User LED 2
User LED 3
User LED 4
(default: SATA activity)
User LED 5
Table 5: System LED values