5 Interfaces

5.6 Digital I/O

The digital I/O interface provides two input and two output groups. Each group has eight signals
and all groups are electrically isolated from each other, as well as from other VisionBox circuits
and interfaces.
The following illustration shows the corresponding electrical equivalent circuit for one input and
one output group:
VisionBox
Galvanic isolation
Current
IN 0
Current
IN 1
IN 7
Current
- / GND
The input group requires external connection of a shared GND reference. For the output group,
the user must provide a supply voltage to the VCC pin which is used by all output signals. Every
input and output has an LED to show the current state of each channel.
Strassheimer Str. 45; 61169 Friedberg - Germany; Tel. +49 6031-6842611; Fax +49 6031-6842612
Limit
Limit
Limit
Figure 16: Simplified digital I/O circuit