3 Technical Data

3.2 Operating Conditions

Power Supply:
Parameter
Supply Voltage
Power Consumption
(at TDP workload)
Power Supply Current Rating
(peak current)
Continuous Supply Current Limit
Environment:
Parameter
Operating Temperature / Recommended Temperature [°C]
for VisionBoxes equipped with Intel CPU 6
Operating Temperature / Recommended Temperature [°C]
for VisionBoxes equipped with Intel CPU 7
Operating Humidity [%, relative, non-condensing]
Storage Temperature [°C]
Storage Humidity [%, relative, non-condensing]
Device Weight [g]
Note: The maximum allowed temperature is influenced by the actual hardware configuration,
the system workload and the mounting situation. The temperature range should be veri-
fied for each application.
Note: The heat sink can transfer more heat in upright mounting position.
Note: Due to the lifetime of electronic components, we recommend not to operate the device
permanently under the maximum possible temperature and instead use a lower than max
temperature. Laws of physics say: if the average operating temperature is increased by
7°C, the lifespan of an electronic component will be divided in half! Following are common
scenarios in industrial applications:
 Multiple devices are mounted inside an electrical cabinet
 The cabinet itself is equipped with an air conditioner.
1
Measured with CPU / GPU at TDP workload and without external devices except 1× Ethernet and DP.
2
Measured with CPU / GPU at full workload; 24 V supply voltage; no external devices except 1× Ethernet link at 1000
Mbit/s. This value doesn't account for additional current drawn by interfaces like 4× Ethernet or for the supply of LED
units and PoE / PoCL / USB devices.
3
Certain possible usage combinations like simultaneous PoE / PoCL / USB device supply and active LED output can
lead to continuous excess of this value, which must be avoided by the user.
Strassheimer Str. 45; 61169 Friedberg - Germany; Tel. +49 6031-6842611; Fax +49 6031-6842612
1
2
3
IMAGO Technologies GmbH
info@imago-technologies.com; www.imago-technologies.com
th
generation
th
generation
Page 13 / 36
Min.
Typ.
Max. Unit
18
24
30
62
2.7
8
Value
+5 ... +45 / +20...+30
+5 ... +40 / +20...+30
5 ... 85
-10 ... +70
5 ... 95
~2500
V
W
A
A