This screen displays raw voltage of the Ref Osc voltage tuning monitor. Use this screen for
debugging purposes only.
These screens display show the PS A and PS B (power supply) 12 V, 8 V, and 5 V values.
Press [ENT] or [CLR] to continue.

6.3.5 (SELECT:) FAULTS Menu Branch

Use the [][] arrow keys to select CURRENT or STORED. Press [ENT].
6.3.5.1

(FAULTS:) CURRENT

These examples are provided for reference only – the data that displays on
your system will vary depending on your actual operating conditions.
Five read-only information screens provide fault monitoring for a number of operating parameters.
The system reports the status as OK (operating within normal ranges), or FT (currently faulted).
Use the [][] arrow keys to page between screens.
LBC-4000:
LBC-4000-ST:
Front Panel Operation
Monitor PS A:
12V=12.3
8V=08.2
5V=05.3
Monitor PS B:
12V=12.2
8V=08.1
5V=05.3
CURRENT
Faults: Conv-A
iflo=OK rflo=OK temp=OK
Faults: Conv-B
iflo=OK rflo=OK temp=OK
Faults: Conv-A
iflo=OK rflo=OK temp=OK
LBC-4000 L-Band Up/Down Converter System
STORED
6–15
Revision 6
MN-LBC-4000