Use the [][] keys to move the cursor to the desired choice. Press [ENT]. The function of each
CONFIG submenu is as follows:
•
LBC-4000: CONV-A, CONV-B Submenus – Displays the current configuration of the
selected converter, including the frequency, attenuation, and slope.
LBC-4000-ST: CONV-A Submenu – Displays the current configuration of the selected
converter, including the frequency, attenuation, and slope.
•
REMOTE Submenu – The selections here allow you to select whether you control the
unit locally or remotely, set the unit address, the interface type, and the operating
parameters for that interface.
•
REDUND Submenu – The selections here allow you to identify the redundancy state and
mode (see Appendix B. REDUNDANCY OPERATION for detailed information about
redundancy operations).
•
REFADJ Submenu – This screen allows you to adjust the reference oscillator.
•
SPECT-INV Submenu – The selections here allow you to set the Converter A and
Converter B spectral inversion to INVERTED or NORMAL.
6.3.3.1
(CONFIG:) CONV-A or CONV-B (Converter Unit A or Unit B)
LBC-4000: Where 'X' is the selected converter – CnvA (Converter Unit A) or CnvB (Converter
Unit B) – and 'YYY' indicates its operating frequency (70 or 140 MHz), use the [][] arrow keys
to select FREQ/MUTE or ATTEN/SLOPE. Press [ENT].
LBC-4000-ST: Where 'X' is the selected converter – CnvA (Converter Unit A) and 'YYY' indicates
its operating frequency (70 or 140 MHz), use the [][] arrow keys to select FREQ/MUTE or
ATTEN/SLOPE. Press [ENT].
(CONFIG:) CnvA or CnvB FREQ/MUTE
6.3.3.1.1
Select the CMM (Configuration Mute Mode): Use the [][] arrow keys on the top line to
select CMM. Use the [][] arrow keys to select ON or OFF.
Set the operating frequency: Use the [][] arrow keys on the bottom line to select a digit to
edit, and then use the [][] arrow keys to change its value. Repeat for all digits until you define
the desired frequency.
Select the Tx/Rx mute status: Use the [][] arrow keys on the bottom line to select the
parameter. Use the [][] arrow keys to select ON or OFF.
The displays reads 'Tx' when the installed module is an Up Converter, or 'Rx'
when the installed module is a Down Converter.
Press [ENT].
Front Panel Operation
CONFIG CnvX:(IF=YYYMHz)
FREQ/MUTE
ATTN/SLOPE
CONFIG CnvX:
Frq=01980.000MHz
LBC-4000 L-Band Up/Down Converter System
CMM=ON
Rx=ON