7 Make sure the stem is aligned in the correct position. Tighten the two rear
stem screws alternately, turning ½ turn at a time, until a minimum torque of
4Nm is reached. If the stem is not tight enough, increase the torque up to a
maximum of 5 Nm. Please check the stem, which should not rotate on the
fork steerer.
WARNING: Always use a calibrated torque wrench to tighten the screws. Use
the minimum tightening torque required to ensure that the stem does not
rotate on the fork steerer (Max. 5 Nm). An unnecessarily high torque generates
a dangerous state of stress on the fork steerer that can create cracks and/or
break without notice and cause serious accidents to the user.
8 Rotate the handlebar to the desired position and tighten alternatively the
faceplate upper and lower screw, ½ rev. each time, up to the reaching of the
tightening torque of 5 Nm.
Check the symmetry and equality of all the distances between faceplate and stem
body, if necessary. The distance between the faceplate and the attachment body
must be the same on the upper and lower part.