Download Print this page
IBO 3SDm Instruction Manual

IBO 3SDm Instruction Manual

Deep-well pumps
Hide thumbs Also See for 3SDm:

Advertisement

Quick Links

Instruction Manual of deep-well pumps of type:
3SDm, 3SD, 3ti, 3t2i, 3SKm, 4SKm, 4SCR, 4SD, 4SDm,
3.5"SCM, 3.5"SCR, 90MSC, 3"SQIBO, STING, DWP, 3"SCR, 4"ISP, 6"ISP,
reading
manual is obligatory
device damage hazard
NOTE: the manual is a primary part of the purchase and sale contract. The user's
failure to observe the instructions included in the manual is a breach of the
contract and excludes any complaints arising from potential device failure
caused by the use that is inconsistent with instructions of its use.
NOTE: failure to observe the instructions included in the manual can
result in hazard for persons, properties in which they are installed,
environment and the pump itself.
CAUTION! This equipment is not intended for use by persons (including children) with
reduced motor, sensory or mental capacities, or persons without experience or not
familiarised with the equipment, unless it is performed under supervision
or according to the instruction regarding operation provided by persons responsible for their safety.
Attention should be paid so that children do not play with the equipment.
APPLICATION:
The pumps referred to in the manual are intended for pumping clean water from bored deep
water intakes or increasing pressure in water systems with the enclosure of the aggregate in a
hermetic jacket.
They can be used in households as water supply, means of irrigation, in heat pump
installations, and to feed water into industrial installations. The pumped water cannot contain
any mechanical contamination.
The pump is intended for pumping of clean water, with no solid- abrasive particles.
Pumping water containing sand results in fast wear and tear of the pump and, in
consequence, it its failure. In such a case, only paid repair is available. The above not
refers to the pumps with increased resistance to sand.
4"ISPm, 4"SCR, OLA, 2,5"STm, 3STm
the
instruction
NOTE: read the manual prior to commencement of use. For safety
reasons, the pump can only be operated by persons well-familiarised.
electrocution hazard
1

Advertisement

loading

Summary of Contents for IBO 3SDm

  • Page 1 Instruction Manual of deep-well pumps of type: 3SDm, 3SD, 3ti, 3t2i, 3SKm, 4SKm, 4SCR, 4SD, 4SDm, 3.5”SCM, 3.5”SCR, 90MSC, 3”SQIBO, STING, DWP, 3”SCR, 4”ISP, 6”ISP, 4”ISPm, 4”SCR, OLA, 2,5”STm, 3STm reading instruction electrocution hazard manual is obligatory device damage hazard NOTE: read the manual prior to commencement of use.
  • Page 2: Pump Installation

    PUMP INSTALLATION: Prior to any installation works, power supply must be disconnected. Provide security against accidental switch-on. Pumps 3ti, 3t2i, 3SDm, 4SD i 4SDm, 4ISP, 4ISPm, 6ISP, 3STm due to their dimensions can be delivered in two elements. One element is a hydraulic part of the pump, the other is a motor.
  • Page 3 The use of the pump in a well with wider diameter than shown in the table can result in motor overheating and its failure. If the well in which the pump is to operate has wider diameter than specified in the table, the pump must be installed in a special jacket forcing the proper cooling.
  • Page 4: Electric Connection

    Prior to lowering of the pump into a new well, a user should ensure that the well company that manufactured the well performed its purification by pumping out water. On well construction the water inside the casing pipe and filter is contaminated with sludge and sand.
  • Page 5 The maximum, acceptable cable length dependent on the diameter of cable cores of the power supply cable Type of Power of the power supplied supply motor [kW] 1x230 V 0.37 1x230 V 0.55 1x230 V 0.75 1x230 V 1x230 V 1x230 V 3x400 V 0.75...
  • Page 6: Device Disposal

    Under the Act of 30 August 2002 on the conformity system (Journal of Laws of 2004, No. 204 item 2087) we declare with full responsibility that pumps included in the series 3SDm, 3SD, 3ti, 3t2i, 3SKm, 4SKm, 4SCR, 4SD, 4SDm, 3,5”SCM, 3,5”SCR, 90MSC, 4SKt, 3SQIBO, DWP, STING, SPm, SP, 3”SCR, 4ISP,6ISP.4ISPM,...
  • Page 7 No power supply Check if the electric plug of the pump is properly inserted into the electric socket. Check fuses at home and all other types of installation fuses that can cut off the power supply from the network Check if there is a power supply in your neighbourhood - power can be cut off by the power plant in the larger area Incorrect voltage or its drop Check the voltage Check if the cable cross-section is sufficient.

This manual is also suitable for:

3sd3ti3t2i3skm4skm4scr ... Show all