Copy Function - Delta DPA Series Instruction Sheet

Pressure sensor
Hide thumbs Also See for DPA Series:
Table of Contents

Advertisement

 Key Locking Function
 Lock On: Press
and
set value (SV).
 Lock Off: Press
and
set value (SV).
 Lock Display: Press any key in the key locking mode, and you will see the display of pressure value (PV) and
key, and the PV and SV will return to original values.
 Switching Colors
In DPA, different output statuses can have different display colors. The output statuses for DPA are "OUT1", "OUT2", "OUT1 and OUT2",
"OUT1 or OUT2". See below explanations for how to set:
1. Setting up output status: In the "Measuring Mode", press
are now in the "Advanced Setup Mode". Press
chart). Use
to select the referencing item you'd like.
2. Switching colors: In the "Measuring Mode", press
and find the parameter for setting up colors (see Quick Setup Mode chart). Use
Note: "OUT1 and OUT2" will be ON only when both OUT1 and OUT2 are ON; otherwise, it will be OFF. "OUT1 or OUT2" will be OFF only
when both OUT1 and OUT2 are OFF; otherwise, it will be ON.
 Copy Function
DPA is able to copy the parameters in the master device to another slave device.
1. Hardware: Connect Pin 2 on master to Pin 3 on slave; Pin 3 on master to Pin 2 on slave; Pin 5 on master and slave to GND on power
supply; Pin 1 on master and slave to +24V on power supply.
2. Software:
a) Slave device: In the "Measuring Mode", press
the "Advanced Setup Mode". Press
Mode chart). Use
b) Master device: In the "Measuring Mode", press
in the "Advanced Setup Mode". Press
Mode chart). Use
to the "Measuring Mode". Now, you will see
have been connected. On
successfully between the two devices. Once the copy of parameter succeeds, you will see
on the slave device. That the number at
After the copy is completed, switch off the two devices and connect them again to the power supply.
 Code
DPA offers codes for the user to set up. In the "Measuring Mode", press
. You are now in the "Advanced Setup Mode". Press
chart).
together for 2 seconds until
together for 2 seconds until
for 5 times and find the switching color referencing items (see Advanced Setup Mode
for more than 2 seconds to enter the "Quick Setup Mode". Press
for more than 4 seconds and release the key after you see
for 7 times and find the parameter for setting up the copy function (see Advanced Setup
to select
(
for 7 times and find the parameter for setting up the copy function (see Advanced Setup
to select
(
, you will see numbering counting up, referring to the number of parameters transmitted
stays intact refers to the copy fails.
displays in turn.
is displayed. You will then see the display of pressure value (PV) and
is displayed. You will then see the display of pressure value (PV) and
for more than 4 seconds and release the key after you see
refers to Copy-Slave).
for more than 2 seconds and release the key after you see
refers to Copy-Master). Next, press
on the screen and
on the slave device, indicating that the two devices
for more than 4 seconds and release the key after you see
for 6 times to find the parameter to set up codes (see Advanced Setup Mode
- 7 -
(SV). Release the
to select the color you'd like.
for more than 2 seconds and return
on the master device and
. You
for 5 times
. You are now in
. You are now

Advertisement

Table of Contents
loading

Table of Contents