Initial Setting; Output Mode Setting - Delta DPA Series Instruction Sheet

Pressure sensor
Hide thumbs Also See for DPA Series:
Table of Contents

Advertisement

Quick Setup Mode
Set up output response time
Set up PV display color
Set up unit
Press
 Return to "set up OUT1 mode"
 Initial Setting
1.
Units: DPA provides many units for users, including kPa, kgf/cm
find
to set the unit to the desired one.
2.
Output status: You can set up 2 output status in DPA, N.O. (normally open) and N.C. (normally closed). In the easy mode, you can press
and fine
3.
Response time: Referring to the time required for the pressure to reach output status. For example, "50" refers to once the pressure has
reached the output status, it has to last for 50ms before the output starts to operate. In the easy mode, press
Use
to set up the response time.
 Output Mode Setting
There are 3 output modes in DPA: Easy, Hysteresis and Window
1. Easy Mode: Set up pressure P. When the pressure measured is bigger than (P + dP), the output will be ON. When the pressure measured
is smaller than P, the output will be OFF. (See Figure 1: Output in Easy Mode)
 In the "Measuring Mode", press
 In the "Advanced Setup Mode", press
2. Hysteresis Mode: Set up pressure Hi/Lo. When the pressure measured is bigger than the Hi value, the output will be ON. When the
pressure measured is smaller than the Lo value, the output will be OFF. (See Figure 2: Output in Hysteresis Mode)
Advanced Setup Mode
Set up power saving mode
Press
Set up switching color referencing
output items
Press
Set up code
Set up copy function
Set up analog output switch
Return to default settings
Press
to set up the output status for OUT1 and OUT2.
and find
and find
[Figure 1: Output in Easy Mode]
Press
Press
Press
Press
Press
 Return to "set up auxiliary
display"
2
, bar, psi, mmHg and inchHg. In the easy mode, you can press
(OUT1) and
(OUT2). Use
. Use
to set up "dP" value.
- 5 -
Measuring Mode
Set up upper limit of OUT2
(Set OUT2 to hysteresis mode / window
mode)
Set up lower limit of OUT2
(Set OUT2 to hysteresis mode / window
mode)
SV of OUT2
(Set OUT2 to easy mode)
Press
 Returning to output setting
and find
to set up P value.
Press
Press
and
.

Advertisement

Table of Contents
loading