Important Notes

Chlorinator Cell Housing Installation
The Ozone Swim cell housing must be plumbed into the return line of the
pool filter system after the filter and any diversion valves.
In situations where a heater is incorporated, the Ozone Swim cell housing
must be installed after the heater. Should a solar heating system be
installed, the housing must be plumbed after the solar diverters and after
the water exits the solar system and re-joins the main stream pool return
line. Ensure there is a gas trap by always installing the chlorinator cell at a
higher level than the filter (see below).
CHLORINATOR
CELL
MEDIA FILTER
SAFE
CARTRIDGE
FILTER
CHLORINATOR
CELL
DANGEROUS
1 2
CHLORINATOR
CELL
CARTRIDGE
FILTER
SAFE
Pump Outlet Socket
A 240 volt pump output power socket is supplied and located on the left-
hand underside of the Ozone Swim control unit. Your pool pump power
supply lead should be plugged into the socket so that when the time clock
switches at the designated times both the Ozone Swim and the pump will
activate in unison.
The pump socket is designed to operate a single pool pump of maximum
1.5 hp (horse power) only. On rare occasions, a 2hp pump will be used as
an integrated solution for in-floor and pool filtration. Do not attempt to
operate any equipment other than your pool pump from this socket as
damage might occur to the Ozone Swim control unit that is not covered
under warranty.
Standard "Non-Flooded" Installation*
from
CHLORINATOR
filter
CELL
INJECTION
MANIFOLD
* Diagram is for illustration purposes only. Does not include all required swimming pool equipment.
OzoneSwim control unit must
be mounted above water level.
For below water level installs,
CONTROL UNIT
see "Flooded System" instructions.
POOL
return to pool