Important Notes

Chlorinator Cell Housing Installation
The Ozone Swim cell housing must be plumbed into the return line of the
pool filter system after the filter and any diversion valves.
In situations where a heater is incorporated, the Ozone Swim cell housing
must be installed after the heater. Should a solar heating system be
installed, the housing must be plumbed after the solar diverters and after
the water exits the solar system and re-joins the main stream pool return
line. Ensure there is a gas trap by always installing the chlorinator cell at a
higher level than the filter (see below).
MEDIA FILTER
CARTRIDGE
FILTER
DANGEROUS
1 2
CHLORINATOR
CELL
SAFE
CHLORINATOR
CELL
CARTRIDGE
FILTER
SAFE
CHLORINATOR
CELL