INSTALLATION

8

Installation Guide

1200i control units
These products must be installed by a qualified installer
MEDIA FILTER
from
PUMP
pool
Note: Install the Ozone Swim control unit a minimum of 900mm above ground level in an area
protected from the elements to eliminate possible damage from severe weather conditions.
Step 1:
Mount Ozone Swim control unit a maximum of 1.5 metres from the filter. Fit two screws into
control unit wall bracket and hang control unit.
Step 2:
Plumb Ozone Injection Manifold after filter. The Injection Manifold should be placed on the
return line to the pool ensuring direction of flow matches the label on the manifold. (Arrow
indicates direction of water flow).
Step 3:
Leave plumbing to cure for a 24 hour period for best results.
Step 4:
Connect supplied Teflon tubing onto the ozone injection manifold stainless steel fittings and the
Ozone Swim Control Unit stainless steel fittings by simply screwing on each end. (Do not over
tighten). See label on Teflon tubing to ensure the correct stainless steel fitting is on the injection
manifold and control unit which ensures correct direction of check valve.
Step 5:
Plug the Ozone Swim power cord into chemical system (salt chlorinator / dosing system). Pool
pump can be plugged into the under casing of Ozone Swim control unit. Switch unit on. The
ozone unit will be controlled by the existing Chlorinator / Chemical controller.
Note: If using a chlorinator, always ensure your pump is running, never allow your chlorinator to
operate without the pump running.
CONTROL UNIT
CHLORINATOR
CELL
INJECTION
MANIFOLD
return
to pool
U s e r M a n U a l