Checking Chlorination Output
The chlorine cell output controller regulates the amount of chlorine
production relevant to the position it has been set to. By adjusting the
cell output controller clockwise, you increase chlorine production and by
turning anti clockwise you reduce production. Do not attempt to turn the
controller beyond its stopping positions as this could cause damage to
your unit that is not covered by warranty.
To ensure your Chlorinator is working correctly, follow the steps below:
• Ensure the cell production is at maximum.
• With the unit running take a sample of water from the skimmer box
and conduct a chlorine test, note the result.
• Take a sample of water directly in front of the return to the pool
outlet and conduct a chlorine test, note the result.
• If the latter is higher in chlorine than the first test, your Ozone Swim
is efficiently producing chlorine (if not please see TROUBLESHOOTING).
Checking Ozone Output
To ensure your Ozone Swim ozone production unit is working follow the
steps below:
• Check that the green ozone light is on.
• Check that there is suction at the air filter on the bottom of the
power pack.
• Check there is bubbles at the return jets when the system is running.
1 8
Chlorine Cell Output Display Definitions
(1000, 2000 & 3000 series only)
Your Ozone Swim unit is fitted with a digital display. During operation of
your Ozone Swim unit the display will illuminate relevant to the degree at
which the chlorine output control has been adjusted. You can increase or
decrease chlorine output to suit your pool's requirements. As you increase
the output (by turning the control knob clockwise), the display will indicate
% of full production capacity / the Amps
reading to the cell. You have full
control of chlorine production merely by adjusting the chlorine controller
and illuminating the number of lights to satisfy your chlorine demand.
The Ozone Swim also has on board diagnostics to indicate any issues with
the system (see table below for definitions).
A value in the range of 1-15, 25 or 30 indicates the Amperage
1-xx
current being applied to the cell.
Cell output control knob is turned off, the Ozone Swim's
OF
chlorination has been manually switched off.
Automatic cleaning cycle beginning, the self-cleaning function is
dg
beginning. This is only displayed for a short period.
(Flashing) There is insufficient water flow through the cell to
Pb
produce. if this persists, please refer to troubleshooting.
OL
(Flashing) overload condition (see troubleshooting).
U s e r M a n U a l
1 9