10.6 Disassembling and Cleaning the Silencer Inserts
1. Unscrew the screws (1) on the gripper head
2. Remove the retaining plate (2)
3. Remove the damping elements (3, 4)
The damping elements can be cleaned with a soft brush.
10.7 Replacing Articulated Connectors
The movements of the swiveling unit may cause the articulated connector plate (part no. 10.01.11.04434)
to wear.
1. Remove the retaining ring (1)
2. Remove the bolt (2)
3. Unscrew the fitting screw (3)
4. Remove the articulated connector plate (4)
EN-US · 30.30.01.02459 · 00 · 08/20
1
2
3
4
1
4
Maintenance
2
3
31 / 36