6.3   Electrical Connection
DANGER
Electric shock from touching live components
Serious injury or death!
4 Make sure that the electrical components are not live before installation, maintenance
and troubleshooting.
4 Switch off the mains switch and secure against unauthorized restart.
A vacuum switch is installed on all gripper types. The connection is established using a 4-pin M8 plug inte-
grated in the vacuum switch. Observe the operating instructions for the vacuum switch (> See ch. Other
Applicable Documents).
6.4   Pneumatic connection
1. Shorten the hoses and pipelines as much as possible.
2. Keep hose lines free of bends and crimps.
3. Lay hose lines in such a way that they do not rub.
CAUTION
Compressed air or vacuum in direct contact with the eye
Severe eye injury
4 Wear eye protection
4 Do not look into compressed air openings
4 Do not look into the silencer air stream
4 Do not look into vacuum openings, e.g. suction cups
The pneumatic connections and their function are described in detail in the chapter "Product Descrip-
tion."
If you do not want to use the "blow-off function" on the gripper, close the "P2" connection with a plug.
Alternatively, you can also use the appropriate quick-change adapter (> See ch. Accessories).