ELECTRICAL CONNECTIONS

It is advisable to leave the control box off the sub-base while completing the
electrical connections to the burner.
The burner may be controlled using either a DIRECT LINE VOLTAGE control
circuit (120V AC 60 cycle) OR a LOW VOLTAGE control (24V AC 60 cycle)
using a R8038A Honeywell switching relay or equivalent.
Using the appropriate diagram below, make electrical connections to the
burner. All wiring must be done in accordance with existing electrical codes,
both national and local.
When all electrical connections have been made, the control box may be put
back in place on the sub-base.
WARNING: DO NOT activate burner until proper oil line connections have
been made, or failure of the pump shaft seal may occur.