JASON Hydrotherapy Integrity A6060 Owner's Manual

Whirlpool baths
Hide thumbs Also See for Integrity A6060:

Advertisement

"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118
www.jasoninternational.com
InsTallaTIOn, OPeraTIOn, anD MaInTenanCe
If the carton shows sign of damage, inspect
the product before accepting and describe the
problem on the Bill of lading.
INSPECTION
Inspect the unit prior to installation. In the event of a
problem, DO NOT install the unit. All components are
factory assembled to the bath and the unit is water tested
and inspected prior to leaving Jason International, Inc.
If the carton shows sign of damage, inspect the product before
accepting and describe the problem on the Bill of Lading.
Note: Transportation and insurance from Jason's factory are
the buyer's responsibility.
Damage sustained in transit is the responsibility of
the carrier. If damage is discovered, the carrier must
be immediately notified in writing with a request for a
representative to inspect the unit. Failure of the carrier to
respond should be reported to the seller and carrier. Always
file a freight claim promptly.
The installer is responsible for insuring that the unit is free
from defects or shipping damage. In the event of a problem,
DO NOT install the unit. Jason International is not responsible
CauTIOn: DO nOT lIfT Or hanDle The BaTh BY ITs PluMBIng.
Owner's reCOrD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
Owner's Manual
Integrity
whirlpool Baths
®
Page 1 of 9
for damage that might have been avoided by inspection or
testing prior to installation.
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer.
ALL WARRANTY CLAIMS ON ACRYLIC SURFACE
DAMAGE MUST BE MADE PRIOR TO INSTALLATION.
Inspect plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage keep the bath in the carton
until ready for installation.
EQUIPMENT ACCESS
In accordance with Building Codes, service access to all
therapy bath equipment, controls and electrical connections
must be provided during installation (see Table 1 –
Specifications for minimum access size). Insufficient access
will hinder repair and maintenance. Warranty service will not
cover costs of providing equipment access.
Jason offers an optional removable lateral skirt for all
rectangular baths. The skirts are available in matching acrylic
colors and provide convenient access to bath equipment as
well as an excellent finished appearance.
PlaCe serIal nuMBer CarD wITh
PrODuCT COnfIguraTIOn In ThIs BOx
49-1013-100
Date 02/11
Customer Service : 800.255.5766

Advertisement

Table of Contents
loading

Summary of Contents for JASON Hydrotherapy Integrity A6060

  • Page 1 “TO BE REMOVED FOR USE BY THE OCCUPANT.” Jason International, Inc. 49-1013-100 8328 MacArthur Drive North Little Rock, AR 72118 Date 02/11 www.jasoninternational.com Owner’s Manual Integrity whirlpool Baths ® InsTallaTIOn, OPeraTIOn, anD MaInTenanCe If the carton shows sign of damage, inspect for damage that might have been avoided by inspection or testing prior to installation.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS TaBle 1 - sPeCIfICaTIOns (cont.) TaBle 1 - sPeCIfICaTIOns Integrity whirlpool Integrity whirlpool Operat- Operat- Overall Min. size Overall Min. size floor floor Dimension Pump access Dimension Pump access loading loading Model Capacity Model Capacity l x w x h (in.) w x h (in.) l x w x h (in.) w x h (in.)
  • Page 3: Installation

    INSTALLATION INSTRUCTIONS (cont.) INSTALLATION 4. Finish plumbing rough-in of drain and overflow assembly. At this time, considerations should be made for the See the USER MAINTENANCE INSTRUCTIONS section position and mounting of the faucet set, as well as all related plumbing. of this owner’s manual, prior to installation, for humidity and mold prevention suggestions.
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) Figure 3 ELECTRICAL service from the GFCI to the bath control should be direct and not interrupted by a switch. Never use a switch in Electrical Power Supply: These instructions are written conjunction with a control device. This will VOID THE assuming 60Hz, 120v power supply.
  • Page 5: Water Testing

    INSTALLATION INSTRUCTIONS (cont.) cord. Connect the pump to a GFCI (Ground Fault Circuit CLEANING Interupter) with 240v (volt), 15A (amp), 60HZ (hertz) elec- 1. Remove all loose debris. Construction plaster or excess trical service with a service ground receptacle dedicated grout can be removed with the use of a wood (edge) for use by this bath.
  • Page 6: Filling And Draining

    OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS INTRODUCTION AIR ON/OFF BUTTON The Air On/Off button provides a safe This manual contains all of the information needed for the proper operation of this Integrity Whirlpool bath. The Whirlpool and convenient method for controlling ®...
  • Page 7: User Maintenance Instructions

    USER MAINTENANCE INSTRUCTIONS HUMIDITY SURFACE MAINTENANCE Warning: Avoid high humidity levels in your home. Areas with minor scratches or dull surfaces can be restored Mold, mildew, fungi and bacteria which may be harmful by applying commercially available plastic polish (i.e. Novus to health thrive in areas with continued high humidity Plastic Polish No.
  • Page 8: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE If the unit is within the warranty period, contact Jason Customer service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the pump.
  • Page 9: Important Safety Instructions

    IMPOrTanT safeTY InsTruCTIOns InsTruCTIOns PerTaInIng TO The rIsk Of fIre, eleCTrIC shOCk, Or InJurY TO PersOns. warnIng: when using this unit, basic precautions should always be followed, including the following: This manual contains information and instructions for proper operation and maintenance of the hydrotherapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire.

Table of Contents