Connecting Battery - Centurion LEVER4 Installation Manual

Swing gate operator
Table of Contents

Advertisement

13.2 Connecting Battery

CP77
CP4 BATTERY
NOTE: IF A LARGE BATTERY IS USED, THE CABLES
CONNECTING THE BATTERY TO THE CP80 CARD
SHOULD BE BETWEEN 6 & 10 mm
LENGTHS LESS THAN 5 METRES.
13.3 Control Card Setup
GATE STATUS
LED (RED)
STATUS LED TABLE
GATE STATUS
LED
LED OFF
GATE CLOSED
LED ON
GATE OPEN
FAST FLASH
CLOSING
SLOW FLASH
OPENING
2 FLASH/2 SECS
MAINS FAILURE
3 FLASH/2 SECS
BATTERY LOW
COMMISSIONING INSTRUCTIONS
IDENTIFY STATUS LED WHICH WILL GIVE INFORMATION ON GATE STATUS (e.g. WHETHER GATE
SHOULD BE OPEN OR CLOSED).
SELECT DIP SWITCH SETTINGS TO GIVE REQUIRED MODE OF OPERATION.
SELECT "AUTOCLOSE" IF REQUIRED (USE SW1).
SET AUTOCLOSE TIMER POTENTIOMETERS TO MINIMUM INITIALLY AND ADJUST TIME TO SUIT AFTER
COMMISSIONING.
SET COLLISION SENSITIVITY POTENTIOMETERS TO MID POSITION (SEE PAGE 20 FOR CORRECT FINAL
ADJUSTMENT).
+
-
BATTERY
12V
²
FOR CABLE
AUTOCLOSE TIMER
1
2 3 4
1
x x
5 SECS
45 SECS
SWITCH NO
4
1
2
3
DESCRIPTION OF OPERATION (MODE)
1
0
0
0
LEVER MOTOR(S) WITHOUT AUTOCLOSE
1
0
1
0
LEVER MOTOR(S) WITH AUTOCLOSE
1
20
20
CONTROLLER
MODEL
CP77
COLLISION SENSITIVITY
SEE PAGE 20
x x x x x x x x
16
+
-
2
4mm
CABLE
F
GREEN POWER ON LED
(ON WITH MAINS POWER PRESENT)
CP77
x
G

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lever5Lever4smaLever4dmaLever5smaLever5dma

Table of Contents