Cable length (9.6 kBits/s) ........................................................................................................................................................ ≤ 1 200 m
Cable: twisted pairs, shield connected to PE on one side ......................................................................................... min. J-Y(St)Y 2 x 0.6
Terminating resistor.............................................................................................................. 120 Ω (0.25 W), internal, can be connected
Device address, BMS bus, Modbus RTU ................................................................................................................................. 3...90 (3)*
Switching elements
Switching elements .................................................................................................................. 2 x 1 N/O contact, common terminal 11
Operating principle .........................................................................................................N/C operation/N/O operation (N/O operation)*
Electrical endurance under rated operating conditions, number of cycles
Contact data acc. to IEC 60947-5-1:
Utilisation category .............................................................................................................. AC-12.....AC-14.....DC-12.....DC-12.....DC-12
Rated operational voltage ......................................................................................................230 V......230 V......24 V......110 V......220 V
Rated operational current .....................................................................................................5 A........2 A.........1 A.........0.2 A..........0.1 A
Minimum contact rating ....................................................................................................................................... 1 mA at AC/DC ≥ 10 V
Environment/EMC
EMC ............................................................................................................................... IEC 61326-2-4, IEC 61851-21-2:2018-04 Ed. 1.0
Ambient temperatures:
Operation ........................................................................................................................................................................... -40...+70 ºC
Transport ........................................................................................................................................................................... -40...+85 ºC
Storage .............................................................................................................................................................................. -40...+70 ºC
Classification of climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .....................................................................................3K24 (except condensation and formation of ice)
Transport (IEC 60721-3-2) ............................................................................................2K11 (except condensation and formation of ice)
Long-term storage (IEC 60721-3-1) ..............................................................................1K22 (except condensation and formation of ice)
Classification of mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ........................................................................................................................................................3M11
Transport (IEC 60721-3-2) ..................................................................................................................................................................2M4
Long-term storage (IEC 60721-3-1) ................................................................................................................................................ 1M12
Connection
Connection type .........................................................................................................................................................push-wire terminal
Nominal current ............................................................................................................................................................................. ≤ 10 A
Cross section ...........................................................................................................................................................................AWG 24 -14
Stripping length ........................................................................................................................................................................... 10 mm
Rigid ..................................................................................................................................................................................0.2...2.5 mm
Flexible without ferrules ................................................................................................................................................. 0.75...2.5 mm
Flexible with ferrules with/without plastic sleeve ......................................................................................................... 0.25...2.5 mm
Multi-conductor flexible with TWIN ferrules with plastic sleeve ........................................................................................0.5...1.5 mm
Opening force .................................................................................................................................................................................... 50 N
Test opening, diameter ............................................................................................................................................................... 2.1 mm
Other
Operating mode ..................................................................................................................................................... continuous operation
Mounting ............................................................................................................................... cooling slots must be ventilated vertically
Degree of protection, built-in components (DIN EN 60529) .............................................................................................................. IP30
Degree of protection, terminals (DIN EN 60529) ............................................................................................................................... IP20
Enclosure material ..............................................................................................................................................................polycarbonate
DIN rail mounting acc. to ..........................................................................................................................................................IEC 60715
Screw mounting ..............................................................................................................................................2 x M4 with mounting clip
Weight ..........................................................................................................................................................................................≤ 150 g
ISOMETER® isoCHA425HV with AGH420-1
isoCHA425HV_D00404_00_M_XXEN / 10.2020
10,000
2
2
2
2
41

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISOMETER isoCHA425HV and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Isometer agh420-1

Table of Contents