2.1
UNPACkING THE COMBUSTION CHAMBER
Carefully lift the combustion chamber out of the carton. Remove the loose item
packaging carefully from the pack. Check the contents as listed :-
DO NOT UNDER ANY CIRCUMSTANCES USE THIS APPLIANCE IF THE
GLASS PANEL IS BROkEN OR NOT SECURELY FIXED TO THE FIREBOX.
Packing Check List
1 off
Combustion chamber & glass frame assembly
1 off
Trim (packed in front section of outer carton)
1 off
Boxed ceramic fuel-bed set (packed inside combustion chamber)
1 off
Installation / user Instruction manual
1 off
Rubber grommet (to seal inlet aperture used on firebox)
1 off
Handset
1 off
Loose Items pack – containing :-
IMPORTANT NOTE BEFORE PROCEEDING WITH THE INSTALLATION
This product requires a minimum effective flue height of 4.0 metres of minimum
circular cross-sectional area 125mm. If installing the product into a 225mm x
225mm brick chimney, THE CHIMNEY SOUNDNESS MUST BE CHECKED BY
TESTING prior to a decision being made on whether the chimney requires lining.
If the flue height is greater than 10 metres on an external wall or 12 metres on an
internal wall then a flue liner must be fitted even if the chimney integrity is ok.
Please check the chimney height and integrity prior to proceeding with the
installation, to establish if a chimney liner is required. Any flue pipe should
conform to BS 715 / BS EN 1856-2 (Metal flue pipes for gas appliances).
When you have decided upon if the product requires the fitting of a flue
liner, proceed with the creation of the correct sized builders opening or
studwork installation of the product as per sections 2.2 or 2.3
SECTION 2
INSTALLATION OF FIRE
6
1 off efficiency baffle & 2 fixing
screws
4 off No. 12 x 40mm screws
4 off rawlplugs
5 off AA batteries
1 off guarantee card