Information And Requirements; Appliance Information - Flavel Rocco HE FPHL RN2 Series Installation, Maintenance & User Instructions

High efficiency log effect room heater
Table of Contents

Advertisement

1.0

APPLIANCE INFORMATION

Main injector : (1 off)
Pilot Type :
Max. Gross Heat Input :
Min. Gross Heat Input :
Gas Rate :
Cold Pressure :
Ignition :
Electrode Spark Gap :
Packed Weight
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 + A1 2013 and the result is 73.9%.
The net calorific value of the fuel has been used for this efficiency
calculation. The test data from which it has been calculated has been certified by
BSI. The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
Fig. 1
Top View of Combustion
Chamber
SECTION 1

INFORMATION AND REQUIREMENTS

Stereomatic Injector Cat 82 – size 380 (NG)
ERTA  PG-83-10
5.4 kW
3.0 kW
0.512 m 3 /hr (High)
0.290 m 3 /hr (Low)
G20
20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
Integral to gas valve
4.0mm
51.0 kg
Fig. 2
Side View of Combustion
Chamber
3

Advertisement

Table of Contents
loading

Table of Contents