3.1.7
Fit Log "F" into position at right hand side of centre of the fuel-bed base
log "A"as shown below in figure 22, using the groove in Log "A" as a
guide for placement.
Fig. 22
3.1.8
Fit Log "G" into position at right hand side of the fuel-bed base log "A"as
shown below in figure 23, using the raised section in the base log as a
guide for position.
Fig. 23
IMPORTANT NOTE
HAVING FITTED THE GRAVEL MATERIAL IN THE BASE OF THE
COMBUSTION CHAMBER, ENSURE THAT NONE OF IT IS ON THE BURNER
FLAME STRIP OR IN THE PILOT ASSEMBLY. IF MATERIAL IS OBSERVED
VISUALLY ON THESE COMPONENTS, REMOVE THE FUEL-BED LOGSET,
REMOVE THE GRAVEL MATERIAL FROM THE BURNER AND OR PILOT AND
RE-FIT THE LOGS AS DETAILED IN SECTION 3.1 ABOVE.