5.2 ABOUT YOUR NEW ROCCO HE ROOM HEATER
The Flavel Rocco High Efficiency log effect room heater incorporates a unique and
highly developed fuel bed which gives the realism of a loose log layout
combined with realistic flames and glow. The use of durable hard ceramic material
in the construction of the fuelbed components ensures long and trouble free
operation. When first using the new fire a slight smell may be noticed. This is due
to small deposits of oil on the firebox, but will soon disappear. Please take the
time to fully read these instructions as you will then be able to obtain the most
effective and safe operation of your fire.
DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO USE THIS APPLIANCE
IF THE GLASS PANEL IS BROkEN OR HAS BEEN REMOVED.
IMPORTANT SAFETY INFORMATION
WARNING : This appliance has a hot surface and as with all heating
appliances a fireguard should be used for the protection of children, the
elderly and infirm. Fireguards should conform to B.S. 8423 : 2002
(Fireguards for use with gas heating appliances). Servicing should be
carried out annually by a competent person such as a GAS SAFE registered
engineer. It is a condition of BFM Europe Ltd. lifetime guarantees schemes
that this is carried out by a competent person i.e a GAS SAFE registered
Engineer.
The service should include visually checking the appliance, flue terminal and
fireplace for accumulation of debris around the firebox, and inspection of the
ceramic logs, replacing as necessary. Should debris be found upon the fuel-bed,
please contact a GAS SAFE registered installer. The condition of the ceramic log
set should be carefully checked and if necessary the whole unit should be
replaced with a genuine replacement set.
After any servicing work a gas tightness check must always be carried out.
Any debris or deposits should be removed from the log set from time to time. This
may be carried out by referring to the cleaning section as described later in this
book. Only the fuelbed components as supplied must be used and complete and
genuine replacements must be used. Always keep furniture and combustible
materials well clear of the fire and never dry clothing or items either on or near to
the fire. Never use aerosols or flammable cleaning products near to the fire when
it is in use.
5.3

SPILLAGE MONITORING SYSTEM

This appliance is fitted with a spillage monitoring system which shuts down the fire
if the evacuation of combustion products from the fire is affected by a partially or
fully blocked flue pipe. If this system operates the fire will go out. If this occurs,
leave the fire for at least three minutes then follow the lighting procedure as
described in the previous section.