Flavel Rocco FBFL RN3 Series User Instructions

Log effect balanced flue room heater

Advertisement

Quick Links

Rocco
Model No. FBFL**RN3
LOG EFFECT BALANCED FLUE ROOM HEATER
User Instructions
These instructions should be read by the user before operating the
appliance and retained for future reference
Model No. FBFL**RN3 is for use on Natural Gas (G20) at a supply pressure
of 20 mbar in G.B. / I.E.
** Denotes trim & colour variant

Advertisement

Table of Contents
loading

Summary of Contents for Flavel Rocco FBFL RN3 Series

  • Page 1 Rocco Model No. FBFL**RN3 LOG EFFECT BALANCED FLUE ROOM HEATER User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No. FBFL**RN3 is for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B.
  • Page 2: Installation Information

    INSTALLATION INFORMATION CONDITIONS OF INSTALLATION It is the law that all gas appliances are installed only by a competent (e.g. GAS SAFE Registered) Installer, in accordance with the installation instructions and the Gas Safety (Installation and Use) Regulations 1998 as amended. Failure to install appliances correctly could lead to prosecution.
  • Page 3: Important Safety Information

    ABOUT YOUR NEW ROCCO ROOM HEATER The Flavel Rocco decorative fuel effect balanced flue room heater incorporates a unique and highly developed fuel bed which gives the realism of a loose log layout combined with realistic flames and glow. The use of durable hard ceramic material in the construction of the fuelbed components ensures long and trouble free operation.
  • Page 4: Operating The Fire

    The fuel bed remains hot for a considerable period after use and sufficient time should be allowed for the fire to cool before cleaning etc. The fire must only be operated with the trim as supplied, in position. OPERATING THE FIRE This appliance is designed so the pilot burner runs constantly, and the remote control handset is used to operate the main burner only.
  • Page 5 Lighting the Main Burner (via the Remote Handset) With the pilot burner established it is possible to light the main burner and adjust the gas rate between high and low with the remote control handset. Press the “up” button to light the main burner and adjust the heat input to the maximum setting.
  • Page 6 NOTE : THIS APPLIANCE IS DESIGNED TO WORK SAFELY AND EFFECTIVELY DURING ADVERSE WEATHER CONDITIONS. HOWEVER, DURING SUCH TIMES FLAME DISTURBANCE MAY BE NOTICED. THIS IS NORMAL AND DOES NOT EFFECT OR IMPAIR THE SAFETY OF THE APPLIANCE. CLEANING WARNING : Before attempting any cleaning operation ensure that the fire has been allowed to fully cool.
  • Page 7: Cleaning The Glass Panel

    CLEANING THE GLASS PANEL To clean the glass panel, first ensure that the fire is cool, please note that the glass panel will remain hot for a considerable period when the fire has been switched off. To remove the glass panel, follow the instructions below for removal and re-fitting.
  • Page 8 REMOVAL & RE-FITTING OF THE FUEL-BED LOGSET The gravel material should then be first layed around the base of the combustion chamber as shown below in Fig. 5, leaving the rear section as shown to allow the fitiing of Log “A” Fig.
  • Page 9 Fit Log “B” into position on left hand side of the fuel-bed base log “A”as shown below in Fig. 7 using the groove in Log “A” as a guide for placement. Fig. 7 Fit Log “C” into position on left hand side of the fuel-bed base log “A”as shown below in Fig.
  • Page 10 Fit Log “D” into position on left hand side of the fuel-bed base log “A”as shown below in Fig. 9, using the groove in Log “A” as a guide for placement. Fig. 9 Fit Log “E” into position at centre of the fuel-bed base log “A”as shown below in Fig.
  • Page 11: Important Note

    Fit Log “F” into position at right hand side of centre of the fuel-bed base log “A”as shown below in Fig. 11, using the groove in Log “A” as a guide for placement. Fig. 11 Fit Log “G” into position at right hand side of the fuel-bed base log “A”as shown below in Fig.
  • Page 12 Warning : Use only the logs supplied with the fire. When replacing the logs remove the old logs and discard them. Fit a complete set of logs of the correct type. Do not fit additional logs or any logs other than a genuine replacement set.
  • Page 13 REMOVAL & RE-FITTING OF THE TRIM ASSEMBLY IMPORTANT NOTE : The trim assembly of this product is a working surface and as such will become hot in use. Allow the product and trim to fully cool prior to attempting to remove it. The trim is attached to firebox by 4 off magnets as shown below in figure 24.
  • Page 14: User-Replaceable Parts

    USER REPLACEABLE PARTS The only user replaceable parts on this fire are the fuelbed / coal form, and the handset / ultrasonic receiver batteries, which may be replaced as described in the section overpage. Replacement of any other parts must be carried out by a competent person such as a GAS SAFE registered gas installer.

This manual is also suitable for:

Rocco fbfl22rn3Rocco fbfl21rn3

Table of Contents