Unit Installation

Supplying Power to the Unit

As shipped, each NetVanta 4000 is set to factory default conditions. After installing the base unit and any
option modules, the NetVanta 4000 is ready for power up. To power the unit, ensure that the unit is
properly connected to an appropriate power source (as outlined in the sections below).
NetVanta 4305 (AC) and NetVanta 4430
The AC-powered NetVanta 4305 and NetVanta 4430 units come equipped with an auto-sensing 100 to
250 VAC, 50/60 Hz power supply. All appropriate power cords are included in the shipment of the units.
To power these units, connect the power cable to an appropriately grounded power source.
Install unit in accordance with Article 400 and 364.8 of NEC NFPA 70.
Maximum recommended ambient operating temperature is 50
Previous versions of the NetVanta 4430 were equipped with either a 120 VAC, 50/60 Hz
(1700630G1#120) or 240 VAC, 50/60 Hz (1700630G1#240) power supply. Plugging these
units into an incompatible power source will damage the unit. Refer to the label on the
unit before connecting the unit to the power source.