Error Codes - Graco 17G807 Operation And Parts

Xp and xp-hf pressuretrak pressuretrak pressuretrak kit
Table of Contents

Advertisement

Error Codes

Codes
Error
Error
Codes
Code
Code
Code
Icon
Icon
Icon
Code
Code
Code Name
Alarms
Alarms
Alarms
J4AX
J4AX
J4AX
Differential
J4BX
J4BX
J4BX
Differential
P6AX
Pressure A
P6AX
P6AX
Disconnected
P6BX
P6BX
P6BX
Pressure B
Disconnected
3A3320D
Name
Name
LED
LED Status
LED
Status
Status
Flashing Red
Pressure
(A>B)
Flashing Red
Pressure
(B>A)
Flashing Red
Flashing Red
Alarms, Deviations, and Advisories
Cause
Cause
Cause
Ran out of B side material. Refill hopper or change
Cavitating B side pump.
B material leaking.
No mix manifold B side
restriction.
A side hose is too small.
Too much B side offset in
control setup.
Improper configuration.
Ran out of A side material. Refill hopper or change
Cavitating A side pump.
A material leaking.
Too much restriction
on mix manifold B side
restriction.
* B side hose is too small.
* No B side offset in
control setup.
Improper configuration.
Broken cable.
Disconnected cable.
Broken cable.
Disconnected cable.
Solution
Solution
Solution
drum.
Warm material or add feed
pressure.
Follow pump
troubleshooting in XP70
Sprayer manual.
Add restriction to B side
on mix manifold to balance
pressures.
Change to larger hose
size.
Adjust B side offset
in setup screens if B
normally runs at a higher
pressure than A.
Adjust setpoints on setup
screens. See
Setup Mode
Details, page
22.
drum.
Warm material or add feed
pressure.
Follow pump
troubleshooting in XP70
Sprayer manual.
Reduce restriction to B
side on mix manifold.
Change to larger diameter
hose size.
Adjust B side offset in
setup screens if B nor-
mally runs at a higher
pressure than A. See
Setup Mode Details, page
22.
Adjust setpoints on setup
screens. See
Setup Mode
Details, page
22.
Replace transducer.
Connect cable.
Replace transducer.
Connect cable.
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

17g80817n936

Table of Contents