Set the system parameters before spraying. These
can be changed as necessary. Press and hold any of
the four keys on the User Interface Display for three
seconds and the XP PressureTrak will enter into the
Setup Mode.
Setup mode screens enable the user to view or
modify system configuration data. The user can set:
• Units of pressure
• Differential pressure deviation value
• Differential pressure alarm value
• High pressure limit value
• Minimum spray pressure value
• Normal B pressure offset value
22
User Setup
Setup
User
Setup
Setup Screen
Setup
Setup
Screen 1 1 1
Screen
Setup Screen 1 enables the user to set units of
measurement that will display on other screens,
pressure warning and pressure alarm. Additionally,
this screen displays the software number and version.
Refer to the following table for more information.
Icon
Function
Icon
Icon
Function
Function
Deviation Pressure
Deviation
Deviation
Pressure
Pressure
Adjust the differential pressure deviation
setpoint.
Default: 400 psi (2.75 MPa, 27.5 Bar)
Range: 0–2000 psi (13.8 MPa, 138 Bar)
Alarm Pressure
Pressure
Alarm
Alarm
Pressure
Adjust the differential pressure alarm
setpoint.
This is the main setting that determines
how far apart the A and B pressures can
be before shutting down the machine.
If the machine shuts down too easily,
increase this to a higher setpoint.
Default: 600 psi (4.13 MPa, 41.3 bar)
Range: 0–2000 psi (13.8 MPa, 138 Bar)