Connection

Before connecting or disconnecting the cables, the
supply lines to the battery and traction vehicle must be
disconnected!
Connection wires / handling the flat pin bushings
Push the insulated cover over
the wire.
Remove 5 mm of the the insulation.
Push the flat pin bushing on-
to the wire until it will go no
further – the bare part of the wire
must lie in the front terminal.
Now press the flat pin bushing
onto the wire using a suit-
able crimping tool.
Check that the flat pin bushing
sits tight on the wire.
Push the insulated cover over
the flat pin bushing.
13-pin coupling plug connection
Wire the caravan's coupling
plug as specified in ISO 11446
and install a fuse (fuses are not
included in the delivery).
16
Energy source / consumer connection
Connect the device to the energy source (e.g. battery, dynamo,
charger) and the consumers (e.g. refrigerator) as shown in
the wiring diagram. Check that the terminals are connected
correctly.
fied cable cross-sections (see table) and fuses of the correct
strength!
5 mm

Cable lengths and cross-sections

* Wire length = wire path x 2
8
7
9
1
6
10
4
2
5
3
11
13
12
Always position the fuses close to the energy source
(e. g. battery, dynamo, charger). Only use the speci-
Check all connections are tight.
Connect the caravan to the traction vehicle via the coupling
plug (see "Commissioning").
Cable
Cable
length *
W 1
W 2
3 m –
Cable
cross-section
3 m
2.5 mm²
3 m
2.5 mm²
6 m
4.0 mm²

Advertisement