Technical Data

Battery voltage
DC voltage 10 V – 15 V
Output voltage
Output battery II, DC voltage controlled 14.2 V
Output refrigerator, DC voltage not controlled
Output current
7 A
Temperature
Ambient temperature from -25 °C to +35 °C
During operation, the casing may heat up to around 70 °C
Cooling
By convection
Configuration
In accordance with the VDE provisions and the device
safety law

Dimensions / weight

Casing
Aluminum
Length
156 mm
Width
119 mm
Height
66 mm
Weight
0.55 kg
The right to effect technical modifications is reserved!

Troubleshooting

Error
Rectification
The battery
Test and if necessary replace the 15 A
does not
fuse – output battery II.
charge.
Check the connections and ensure that
they are connected to the right terminals.
Check the coupling plug.
No power
Test and if necessary replace the 15 A
supply to the
fuse – refrigerator.
refrigerator
Check the connections and ensure that
they are connected to the right terminals.
Check the coupling plug.
If these measures do not solve the problem, please
contact the Truma Service Centre.