CONTEC MEDICAL SYSTEMS CONTEC08A-VET User Manual

CONTEC MEDICAL SYSTEMS CONTEC08A-VET User Manual

Vet electronic sphygmomanometer

Advertisement

PROFESSIONAL MEDICAL PRODUCTS
SFIGMOMANOMETRO ELETTRONICO VETERINARIO
VET ELECTRONIC SPHYGMOMANOMETER
TENSIOMÈTRE VÉTÉRINAIRE ÉLECTRONIQUE
ESFIGMOMANÓMETRO VETERINARIA ELECTRÓNICO
ESFIGMOMANÔMETRO VETERINÁRIO ELETRÔNICO
80550 / CONTEC08A-VET
CONTEC MEDICAL SYSTEMS CO., LTD
No.112 Qinhuang West Street, Economic & Technical Development Zone,
Qinhuangdao, Hebei Province, PEOPLE'S REPUBLIC OF CHINA
Made in China
Shanghai International Holding Corp. GmbH (Europe)
Eiffestrasse 80, 20537 Hamburg, Germany
Importato da / Imported by / Importé par / Importado por / Importado por:
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
55°C
95%
1060 hPa
-20°C
0%
700 hPa

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CONTEC08A-VET and is the answer not in the manual?

Questions and answers

Lisa
March 20, 2025

When I take the BP on my dog, it just keeps going and never gives a pressure. Cuff is on properly, is the right size and air plug is in securely. What **** I doing or not doing correctly?

1 comments:
Mr. Anderson
March 20, 2025

Several factors could prevent the CONTEC08A-VET from providing a blood pressure reading on your dog despite proper cuff placement and secure connections:

1. Animal Condition: The device should not be used on animals with damaged skin, sickle-cell disease, or thrombasthemia without clinical evaluation.
2. Incorrect Cuff Size or Pressure: Ensure that the correct cuff size is used and that it is not overinflated, as this may prevent accurate readings.
3. Movement or Stress: If the animal is moving or stressed, it can interfere with measurements. Keep the animal calm and still.
4. Device Lifespan: If the device has exceeded its five-year useful life, it may no longer function properly.
5. Environmental Factors: Ensure the device is not used in conditions with flammable anesthetic gases or if liquid has entered the device.
6. Software or Connection Issues: If using the USB interface to transfer data, check the related software for proper operation.

If issues persist, consult the manual for troubleshooting or contact the service department.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for CONTEC MEDICAL SYSTEMS CONTEC08A-VET

  • Page 1 TENSIOMÈTRE VÉTÉRINAIRE ÉLECTRONIQUE ESFIGMOMANÓMETRO VETERINARIA ELECTRÓNICO ESFIGMOMANÔMETRO VETERINÁRIO ELETRÔNICO 80550 / CONTEC08A-VET CONTEC MEDICAL SYSTEMS CO., LTD No.112 Qinhuang West Street, Economic & Technical Development Zone, Qinhuangdao, Hebei Province, PEOPLE’S REPUBLIC OF CHINA Made in China Shanghai International Holding Corp. GmbH (Europe) 55°C...
  • Page 2 ENGLISH Foreword Please read the User Manual carefully before using this product. The User Manual which describes the operating procedures should be followed strictly. This manual detailed introduce the steps must be noted when using the product, operation which may result in abnormal, the risk may cause personal injury and product damage and other contents, refer to the chapters for details.
  • Page 3: Table Of Contents

    ENGLISH Contents Chapter 1 Safety Precautions ............................. 43 1.1 Operation for AC Adapter (Separate Sale) ..................... 45 1.2 Operation for Battery ..........................45 Chapter 2 Main Unit ..............................47 Chapter 3 External Interfaces ............................50 Chapter 4 Battery/AC Adapter Installation ......................... 52 4.1 Battery Installation ..........................
  • Page 4 ENGLISH Chapter 16 Keys and Symbols ............................70 Chapter 17 Maintenance, Cleaning and Keeping ......................72 Chapter 18 NIBP Specification ............................74...
  • Page 5: Chapter 1 Safety Precautions

    ENGLISH Chapter 1 SAFETY PRECAUTIONS • In order to use it correctly, please read the “Safety Precautions” carefully before using it. • Operators do not need professional training, but should use this product after fully understanding the requirements in this manual. •...
  • Page 6 ENGLISH Dispose of the packaging material, observing the applicable waste control regulations and keeping it out of chil- dren’s reach. Otherwise it may cause harm to the environment or children. Please use approved accessories for the device and check that the device and accessories are working properly and safely before use.
  • Page 7: Operation For Ac Adapter (Separate Sale)

    ENGLISH content, please contact our company. The device shall comply with the standard IEC 80601-2-30:Particular requirements for basic safety and essential perfor- mance of automated non-invasive sphygmomanometers. 1.1 Operation for AC Adapter (Separate Sale) Note The device can be powered by a power adapter that is a part of the medical electrical system. Be sure to use the dedicated medical grade power adapter of this device.
  • Page 8 ENGLISH If electrolyte of the batteries immodestly get in your eyes, immediately rinse with plenty of clean water. It will cause blindness or other hazards, should immediately go to the nearest hospital for treatment. If electrolyte of the batteries immodestly glues on the skin or the clothes, immediately rinse with plenty of clean water.
  • Page 9: Chapter 2 Main Unit

    ENGLISH done automatically. The determination should be based on the clinical evaluation. Ensure that the correct setting and blood pressure cuff are selected when performing measurements on animal. It may be dangerous for the animal to use an over pressure level. The device has normal useful life for five years since the first electrified use.
  • Page 10 ENGLISH Accessories The sphygmomanometer supports cuffs in a variety of sizes, please choose suited cuff according to the size of the animal. USB Data Line Software CD User Manual Optional Accessories AC adapter Input: voltage: AC 100 V~240 V frequency: 50 Hz/60 HZ Rated current: AC 150 mA Output: DC 6.0 V±0.2 V 1.0 A or DC5.0 V±0.2 V 1.0 A...
  • Page 11 ENGLISH Note: because SpO probe measurements are statistically distributed, only about two-thirds of SpO probe measurements can be expected to fall within ±Arms of the value measured by a CO-OXIMETER. B. B. Pulse rate measurement Range:30 bpm~250 bpm Error: ±2 bpm or ±2% (select the larger) Resolution: 1bpm C.
  • Page 12: Chapter 3 External Interfaces

    ENGLISH Note • The cuff is a consumable. Calculate by measuring 6 times a day(3 times each morning and evening), the service life of the cuff is about 1 year.(using our experimental conditions) • In order to correctly measure blood pressure, please replace the cuff in time. •...
  • Page 13 ENGLISH The right side of the device is USB socket and power adapter socket • USB socket ( is USB identifier) Right side • Power adapter socket ( is power socket identifier) Note All analog and digital equipment connected to this device must be certified to IEC standards (such as IEC60950: Information technology equipment-Safety and IEC60601-1: Medical electrical equipment-Safety), and all equip- ment should be connected to in accordance with the requirement of the valid version of the IEC60601-1-1 system standard.
  • Page 14: Chapter 4 Battery/Ac Adapter Installation

    ENGLISH Chapter 4 BATTERY/AC ADAPTER INSTALLATION The product can use battery or AC adapter as power source. 4.1 Battery Installation 1. Demount the battery cover in the direction of the arrow. 2. Install “AA” batteries according to + - polarities. 3.
  • Page 15: Usage Of Power Adapter

    ENGLISH 4.2 Usage of power adapter 1. Connect the sphygmomanometer and the power adapter. Insert the power adapter plug into the power adapter socket on the right side of the device. 2. Please insert the power plug of the adapter into the AC 100 V~240 V socket. Note The device can be disconnected from the power supply network by unplugging the adapter plug.
  • Page 16: Chapter 6 Setting The Date And Time

    ENGLISH • At all levels interface, the three buttons correspond respectively with the text prompts below the LCD screen, pressing any button will carry on the corresponding function, eg: [MENU] [ENTER] [LIST] [USER] etc. • Up and down buttons, respectively carry on the functions of moving the cursor up and down, changing the param- eters and switching the status..
  • Page 17: Chapter 7 About Unit

    ENGLISH Note The range of year is from 2010 to 2099. When the year reaches 2099, pressing the [UP] button will return to 2010. Chapter 7 ABOUT UNIT There are two units: “mmHg” and “kPa”. The default is: “mmHg”. Enter the [SYSTEM SETUP] submenu in [SYSTEM MENU], then select [UNIT] option to switch units between “mmHg” and “kPa”.
  • Page 18: Chapter 8 Over-Limit Prompt Function

    ENGLISH Chapter 8 OVER-LIMIT PROMPT FUNCTION The Sphygmomanometer has two kinds of reminding methods: the technical parameter over-limit prompt and the physio- logical parameter over-limit prompt. 8.1 Physiological parameter over-limit prompt The sphygmomanometer has the function of over-limit prompt, the user can press [MENU] button to enter system menu, select [PROMPT SETUP] option to enter its interface, then set the limit value of blood pressure.
  • Page 19: Technical Parameter Over-Limit Prompt

    ENGLISH 8.2 Technical parameter over-limit prompt When power is about to exhaust and prompt is ON, the prompt will occur. This prompt can not be canceled unless being closed or the power replaced. Chapter 9 THE USAGE METHOD OF SPHYGMOMANOMETER 9.1 Accurate Measurement Way The limb chosen for taking the measurement should be placed at the same level as the animal’s heart.
  • Page 20 ENGLISH Repeated measurement for a long period of time, limbs rubbing with the cuff may be accompanied by purpura, ischemia and nerve damage. When measurement a animal, it is necessary to frequently check the color, warmth and sensitivity of the distal of the limb. Once any abnormalities are observed, place the cuff in another position or stop the blood pressure measurement immediately.
  • Page 21: Applying The Cuff

    ENGLISH 9.2 Applying the Cuff The measurement can be carried out by applying the cuff on left or right forelimb. Carry out the operation in a room with comfortable temperature. Wear the cuff accurately following these steps: 1. Make sure the air plug is securely inserted in the main unit. 2.
  • Page 22: Bp Measurement

    ENGLISH 9.3 BP Measurement In order to measure accurately, pay attention to applying the cuff properly. Select a proper cuff according to different ani- mals, then select proper cuff type(large, middle and small). There are two ways to select the cuff mode, in the time interface, press CUFF button to switch cuff mode; or enter the [SYSTEM SETUP] submenu in [SYSTEM MENU], and complete switching in [CUFF TYPE] item.
  • Page 23 ENGLISH The measurement value can be stored automatically, using [memory function] (refer to Chapter11). *Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician. Note • Wait at least 4-5 minutes between measurements When repeatedly measuring, the accurate blood pressure value may not be measured due to congestion in the limbs. Please measure after the blood flow is smooth.
  • Page 24: Chapter 10 Memory Function

    ENGLISH Chapter 10 MEMORY FUNCTION The sphygmomanometer is designed to store the blood pressure, pulse rate values and the date and time when measured, which are up to 100 groups. If there have been stored 100 groups, the earliest results will be deleted when saving the 101 group of measurement results.
  • Page 25: Chapter 11 Spo 2 Measurement Function(Optional)

    ENGLISH Chapter 11 MEASUREMENT FUNCTION(OPTIONAL) Precautions during SpO2 Measurement: Note • Make sure the nail covers the light. The probe cable should be on the backside of the hand. Improper probe placement or improper contact with the test site will influence the measurement. •...
  • Page 26 ENGLISH • The claim for SpO accuracy should be supported by clinical research measurements covering the entire spectrum. By artificially inducing to different stable oxygen levels, make it in the range of 70% ~ 100% of SpO . Use secondary standard SpO measuring equipment for comparison to collect SpO values together with the tested product, compose...
  • Page 27 ENGLISH • Excessive ambient light may affect the measuring results, such as surgical light (especially xenon light sources), bilirubin lamp, fluorescent lamp, infrared heater and direct sunlight, etc. In order to prevent interference from ambient light, make sure to place the probe properly and cover the probe with opaque material. •...
  • Page 28: Chapter 12 Spo 2 Measurement Method

    ENGLISH Chapter 12 MEASUREMENT METHOD (This chapter is only suitable for European Union market) 1) Put the animal tongue enough into the animal nip of probe as the following figure. Place 2 probe 2) Plug the connector of the SpO probe cable into the USB socket in the lower right of the device.
  • Page 29: Chapter 13 Installation Of The Software

    ENGLISH • Excessive animal movement. • External light. • Improper SpO probe installation or incorrect contact position of the patient. • Temperature of SpO probe(optimal temperature range: 28°C ~ 40°C). • Place the SpO probe on an limb that has a blood pressure cuff, arterial catheter, or intravascular line. •...
  • Page 30: Chapter 14 Error Message

    ENGLISH Open Windows Explorer. Click on the root CD-ROM directory. Double click file setup software. Follow the instructions in the screen. Refer to “Software Help”for details about the operation method of the PC software. Chapter 14 ERROR MESSAGE Error message will be displayed in the screen if there is something wrong when measuring. The causes and solutions are shown as follows: Error Message Causes...
  • Page 31: Chapter 15 Troubleshooting

    ENGLISH Chapter 15 TROUBLESHOOTING Abnormal Phenomenons Causes Solutions Cuff is not connected correctly Correctly connect cuff (refer to Chapter 9) BP measurement values too high or too low Move limbs when measuring Keep quiet and restart a measurement Cuff leakage Buy a new cuff The cuff windpipe is not correctly No pressure...
  • Page 32 ENGLISH No deflation or deflation error or Pull out the cuff to deflate. Stop using the inflation without stop device and contact us Air pressure error Others Keep limbs, body still, measure again No press value displayed or the value unchanged or change erratically Pull out the cuff to deflate.
  • Page 33 ENGLISH 1. No NIBP data to review USB socket connect SpO probe 2. No finger inserted to SpO probe(Optional) (This item only suitable for European Union 3. An indicator of signal inadequacy market) Type BF applied part Class II applied Serial number Socket for power adapter Authorized representative in the European...
  • Page 34 ENGLISH Chapter 17 MAINTENANCE, CLEANING AND KEEPING *Please do obey the precautions and correct operating methods in this user manual. Otherwise, we will not re- sponsible for any fault. Warning Remove the batteries before cleaning. The accessories and main unit must be separated for cleaning. Maintenance is not allowed during device using.
  • Page 35 ENGLISH Advice • Do not use gasoline, volatile oil, diluent, etc. to wipe the device. • Do not clean or wet the cuff. Storage: Advice • Do not expose the device in direct sunlight for long time, otherwise the display screen may- be damaged.
  • Page 36 ENGLISH Chapter 18 NIBP SPECIFICATION Name Electronic Sphygmomanometer Display mode 2.8'' color LCD Display The degree of protection against ingress of water IPX0 NIBP specification Measurement method Oscillometric method Working mode Automatic Operation mode Continuous operation Measurement Range Pressure:0~290 mmHg (0~38.6 kPa) Pulse: 40~240/min Resolution Pressure: 1mmHg(0.133 kPa)
  • Page 37 ENGLISH Atmospheric pressure 700 hPa~1060 hPa Power supply 4 "AA" alkaline batteries, AC Adapter (AC, 100 V-240 V, optional) Rated current ≤ 600 mA Battery life When the temperature is 23 ºC, limb circumference is 270 mm, the measured blood pressure is normal, 4 "AA" alkaline batteries cab be used about 300 times.