EXCELL PRECISION CO., LTD.
3-2-1
Zero value can be calibrated separately from the weight calibration value.
Press
MC
.
No weight display
Make sure that no load on platter,
and press MC to read "Zero"
.
Calibration poises value (weight value of fully capacity)
Use number key 0
~
modify calibration poises value,
place enough poises according to
value entered, and press MC
key to read calibrated internal
value and save into EEPROM.
.
Poises weight value on platter
03004034

External Weight Calibration

If there is no temperature IC, the unit weight column will
display
kg
Press
PRESET CE
Press
if not intend to calibrate "0".
.
kg
Calibration poises value entered can not be higher than "maximum
9
to
weighing capacity".
Poises weight entered will be compared with internal calibration
poises weight. If the actual weight is more than the entered poises
weight in 1.1~0.9 times, the weight column will display
or place the correct weight to operate once again.
If you do not calibrate weight, press
AD data into EEPROM.
kg
Under weight calibration mode, please put on or
remove weight to test. After testing, press MC
key to complete external weight calibration
key
CE
key
TARE
key
MC
key
X X X
.
X X X
to switch calibration unit.
X X X
for 1 second. Re-enter the calibration poises value,
X X X
⇒ ⇒ ⇒ ⇒ Exit
⇒ ⇒ ⇒ ⇒ Move the cursor leftward
⇒ ⇒ ⇒ ⇒ Move the cursor rightward
⇒ ⇒ ⇒ ⇒ Enter
48
X X X X X X
Internal value of no weight display
X X X X X X
Internal value of full capacity display
.
key to exit without saving
X X X X X X
Internal value
ZSME200000051