UMT Map

This list contains all points accessible on the UMT. Setpoints in this list with a solid underline can be
edited. All others are view-only.
AIR FLOW MONITORING
AMD Airflow
AMD Damper Area
AMD K Factor
AMD M Factor
AMD Thermal Dispersion Max Velocity
AMD Transducer Range
Damper Setpoint
Exhaust Airflow
Exhaust Inlet Cone K Factor
Supply Airflow
Supply Inlet Cone K Factor
Type
ALARMS
Alarm Reset
Alarm Status
Clogged Air Filter
CO2 Sensor
Duct Static Pressure
Exhaust Fan
Exhaust Temperature Sensor
Freezestat
Heat Wheel Rotation
High Pressure/Low Pressure Cutout Circuit A
High Pressure/Low Pressure Cutout Circuit B
Mixed Air Temperature Sensor
Outdoor Air Damper End Switch
Outdoor Air Temperature Sensor
Outdoor Relative Humidity Sensor
Refrigerant Pressure Transducer A
Refrigerant Pressure Transducer B
Shutdown Input
Space Humidity Sensor
Space Static Pressure
Space Temperature Sensor
Supply Fan
Supply High Temp Alarm Delay
Supply Temp High
Supply Temp Low
Supply Temperature Sensor
WSHP Low Refrigerant Pressure
BACNET NETWORK ADVANCED
Time Synch
UDP Port Number
CO2 CONTROL
CO2 Control
CO2 Deadband
CO2 Level
CO2 Setpoint
Control Enabled
Maximum Damper Control Position
COOLING
10 Volts Opens Chilled Water Valve
AMB Lockout
Chilled Water Valve Off Position
Compressor 1 Ambient Lockout Setpoint
Compressor 1 Output
Compressor 2 Ambient Lockout Setpoint
Compressor 2 Output
Compressor 3 Ambient Lockout Setpoint
Compressor 3 Output
Valent Controls IOM
Compressor 4 Ambient Lockout Setpoint
Compressor 4 Output
Cooling Execution Time
Cooling Integral Constant
Cooling Proportional Constant
Digital/Chilled Water Output
Enable Compressor 1 Ambient Lockout
Enable Compressor 2 Ambient Lockout
Enable Compressor 3 Ambient Lockout
Enable Compressor 4 Ambient Lockout
High/Low Pressure Trip Shutdown Circuit
Shutdown Unit During High/Low Pressure Trip
DAMPER OPERATION
Damper Configuration
Damper Output
Damper Remote Control
Economizer Configuration
Economizer Enable Setpoint Enthalpy
Economizer Enable Setpoint Temperature
Outdoor Air Damper Maximum
Outdoor Air Damper Minimum
Unoccupied Outdoor Air Damper Minimum
DEHUMIDIFICATION
Dehumidification Has Priority
DX Coil Setpoint
Occupied Space Humidity Low Deadband
Outdoor Dewpoint Deadband
Outdoor Dewpoint Setpoint
Overcool Offset
Space Dewpoint Dehumidification Cutout
Space Relative Humidity Setpoint
Unoccupied Space Humidity Low Deadband
Unoccupied Space Humidity Setpoint
DUCT PRESSURE CONTROL
Duct Pressure
Duct Pressure High Limit Setpoint
Duct Pressure Setpoint
Supply Fan Reaction Speed
ENERGY RECOVERY
Defrost Mode
Flat Plate Exhaust Defrost
Heat Wheel Exhaust Defrost
Heat Wheel Operating Mode
Heat Wheel Output
Heat Wheel Speed/Damper Position
Heat Wheel Status
HW Jog Duty Cycle
HW Jog Period
HW Speed When Economizing
Preheat Ambient Setpoint
Preheat Output
EXHAUST SETTINGS
Configuration
Exhaust Fan Enable Damper Position
Exhaust Fan Max Speed
Exhaust Fan Min Speed
Exhaust Fan Offset
20
FACTORY SETUP
Airflow Monitoring Type
AMD Type
CO2 Control
Communications Type
Cooling Package
Damper Configuration
Economizer
Energy Recovery Configuration
Exhaust Fan Control Type
Future
Future
Heat Pump
Heat Wheel Rotation Sensor
Heating Package
I/O Map
Morning Warm Up
Night Purge
Optimal SS
Pre-Heater
Refrigerant Monitoring
Reheat Dehumidification
Remote Damper Control
Saved Controls Number
Space Setpoint
Supply Fan Configuration
Unit Type
Web UI
FAN OPERATION
Exhaust Fan Output
Exhaust Fan Speed
Exhaust Fan Status
Supply Fan Max Speed Setpoint
Supply Fan Min Speed
Supply Fan Output
Supply Fan Speed
Supply Fan Status
Unoccupied Supply Fan Speed Offset
HEAD PRESSURE;HEAT PUMP
1.0 Air Cooled Head Pressure Setpoint
2.0 Air Cooled Head Pressure
Dehumidification Setpoint
2.0 Air Cooled Head Pressure Setpoint
ASHP Allow Defrost Mode
ASHP Defrost Cancel Condensing Setpoint
ASHP Defrost Status
ASHP Electric Heat Defrost
ASHP Electric Heat Defrost Enable :
CALL VALENT FOR PASSWORD
ASHP Low Ambient Compressor Lockout Setpoint
Head PR Output 1
Head PR Output 2
Refrigerant Pressure Circuit A
Refrigerant Pressure Circuit B
Valve A Output
Valve B Output
WSHP Cold Start Duration
WSHP Cold Start Enable Temp
WSHP Compressor Off Water Valve Position
WSHP Condenser Temperature Setpoint
WSHP Suction Temp Low Limit Safety
WSHP Valve Max Closed Position
IOM-C1-0616