Page 1
OCPRF100 MP Server System Quick Start Guide Order Number: 726994-002 How to do basic set-up, boot from the configuration software CD, install the optional slide rail kit, and access the Product Guide from the CD...
Page 2
Intel. Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document.
Using the PostScript .PS Files ................... 21 Copy Configuration Software to Diskettes ................21 Warnings ..........................22 WARNING: English (US) ....................23 AVERTISSEMENT: Français..................... 25 WARNUNG: Deutsch ......................27 AVVERTENZA: Italiano ..................... 29 ADVERTENCIAS: Español....................31 OCPRF100 MP Server System 3...
Page 4
WARNINGS : Before operating this server, read the warnings ARNINGS beginning on page 22. : To avoid personal injury when unpacking the server, use VOID INJURY only a mechanical assist unit to lift it off the shipping pallet. The minimum server configuration weighs 51 kg (113 lbs); the maximum weighs 63.5 kg (140 lbs).
Server Specifications Table 1. OCPRF100 MP Server Physical Specifications Specification Value Height 31.12 cm (12.25 inches, 7u) Width 44.45 cm (17.5 inches) Depth 71.12 cm (28.0 inches) Weight 51.4 kg (113 lbs) minimum configuration 63.5 kg (140 lbs) maximum configuration Required front clearance 10 inches (inlet airflow <35 °C / 95 °F)
Select Site WARNING The push-button on/off power switch on the front panel of the server does not turn off the AC power. To remove AC power from the server, you must unplug the AC power cord from the server or wall outlet. CAUTION, ESD precautions Electrostatic discharge (ESD) can damage disk drives, add-in boards, and other parts.
Optional Slide Rail Kit If the OCPRF100 MP Server is to be rack mounted the slide rail kit should be installed as follows before proceeding. Equipment Rack Precautions WARNINGS : The equipment rack must be anchored NCHOR THE EQUIPMENT RACK to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies.
Prepare the Slide Assemblies 1. Remove the slide assemblies from the kit. 2. Orient the slide assembly so that the arrow embossed on each rail assembly is facing toward the front of the server as shown in Figure 2. Figure 2. Slide Rail Orientation 3.
Page 9
10. Press the safety latch, and separate the bars. Set the center bar and large outer bar assembly aside to attach to the equipment rack in a later step. 11. Prepare the other slide assembly by repeating steps 2–10 above. OCPRF100 MP Server System 9...
Attach the Rail Slide Rail Brackets to the Equipment Rack NOTE Mounting holes in the vertical rails of equipment racks are commonly spaced in a 5/8 x 5/8 x 1/2-inch sequence. Perform the following steps carefully; brackets must be mounted with precision to allow room for the next server you install in a rack.
Screw C. Flat washer, lock washer, and nut D. Large outer bar Safety latch on the center bar Center bar G. Front right-angle extension bracket OM08047 Figure 7. Center Bar and Large Outer Bar Assembly OCPRF100 MP Server System 11...
Install the Server in the Rack WARNINGS : The equipment rack must be anchored NCHOR THE EQUIPMENT RACK to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs).
• Connector, wall outlet end: Cords must be terminated in grounding-type male plug designed for use in your region. It must have certification marks showing certification by an agency acceptable in your region. OCPRF100 MP Server System 13...
• Connector, server end: The connector that plugs into the AC receptacle on the server must be an IEC 320, sheet C19, type female connector. • Cord length and flexibility: Cords must be less than 4.5 meters (14.76 feet) long, and must <...
Page 15
PS/2-compatible serial ports A and B, 9-pin RS-232 connector Super VGA compatible, 15-pin video connector PS/2-compatible parallel port (LPT), 25-pin bidirectional subminiature D connector USB ports 0 and 1, 4-pin connector Interchassis Management Bus (ICMB) connectors port 1 and 2 continued OCPRF100 MP Server System 15...
Table 2. Back Components, Controls, and Indicators (continued) Item Feature/Description Power Supplies (in this view, supplies must be populated from left to right; the right bay would contain the redundant supply) Failure LED (yellow) Predictive failure LED (yellow) for power supply fan Power LED (green) AC input power connector Turn on Video Monitor and Server...
Page 17
When lit continuously, it indicates an asserted fault status on one or more hard disk drives in the hot-docking bay. When flashing, it indicates drive reset in progress. Front panel LCD Displays information about processor type and failure codes. continued OCPRF100 MP Server System 17...
Table 3. Front Controls and Indicators Item Feature Description Status LEDs for SCSI Drives in Hot-docking Bays Drive power LED (green) When lit continuously, it indicates the presence of the drive and power on the drive. Drive activity LED (green) Indicates drive activity.
The server will, therefore, try to boot from diskette rather than from the CD-ROM. Even with the CD in the drive, the server might continue to display “Operating System Not Found.” Follow the steps in “Change Boot Device Priority” on page 20. OCPRF100 MP Server System 19...
1. Open the CD tray by pressing the open/close button on the front panel of the CD-ROM drive. The tray will slide out of the drive. 2. Open the CD case. Press down on the center hub of the case to release the CD. 3.
2. From the CD-ROM menu bar, select Create Diskettes and press <Enter>. 3. Follow the prompts to copy the software onto the diskettes. 4. When finished, from the CD-ROM menu bar, select Quit to DOS and press <Enter>. 5. Remove the CD from the CD-ROM drive. OCPRF100 MP Server System 21...
Attach the covers to the chassis with the screws removed earlier, and tighten them firmly. Insert and lock the padlock to the system to prevent unauthorized access inside the system. Connect all external cables and the AC power cord(s) to the system. continued OCPRF100 MP Server System 23...
Page 24
WARNING: English (continued) A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts. Contact should be made with care. Consider wearing protective gloves. Danger of explosion if the battery is incorrectly replaced.
Revissez solidement les panneaux du boîtier avec les vis retirées plus tôt. Remettez le cadenas en place et verrouillez-le afin de prévenir tout accès non autorisé à l’intérieur du système. Rebranchez tous les cordons d’alimentation c. a. et câbles externes au système. suite OCPRF100 MP Server System 25...
Page 26
AVERTISSEMENT: Français (suite) Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. Danger d'explosion si la batterie n'est pas remontée correctement.
Schrauben wieder anbringen. Ziehen Sie diese gut an. Bringen Sie die Verschlußeinrichtung (Padlock) wieder an und schließen Sie diese, um ein unerlaubtes Öffnen des Systems zu verhindern. Schließen Sie alle externen Kabel und den AC Stromanschlußstecker Ihres Systems wieder an. fortsetzung OCPRF100 MP Server System 27...
Page 28
WARNUNG: Deutsch (fortsetzung) Der Mikroprozessor und der Kühler sind möglicherweise erhitzt, wenn das System in Betrieb ist. Außerdem können einige Platinen und Gehäuseteile scharfe Spitzen und Kanten aufweisen. Arbeiten an Platinen und Gehäuse sollten vorsichtig ausgeführt werden. Sie sollten Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr.
Attaccare le coperture al telaio con le viti tolte in precedenza e avvitarle strettamente. Inserire e chiudere a chiave il lucchetto sul retro del sistema per impedire l’accesso non autorizzato al sistema. Ricollegare tutti i cavi esterni e le prolunghe AC del sistema. continua OCPRF100 MP Server System 29...
Page 30
AVVERTENZA: Italiano (continua) Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto.
Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. Conecte todos los cables externos y los cables de alimentación CA al sistema. continúa OCPRF100 MP Server System 31...
Page 32
ADVERTENCIAS: Español (continúa) Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes. También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores.