Appendix "B" - Specifications And Dimensions - red lion APOLLO IMH Series Instruction Manual

Table of Contents

Advertisement

APPENDIX "B" - SPECIFICATIONS AND
DIMENSIONS
1. DISPLAY: 6-digit, 0.56" (14.2 mm) High LED. Flashing display during
totalizer overflow. "......" displayed during input display out of range.
"OLOLOL" is displayed during input overload, which is any current greater
than 5.3 amps AC.
2. POWER REQUIREMENTS:
AC Power: Switch Selectable 115/230 VAC, ±10%, 50/60 Hz, 14 VA
3. CONTROLS: Three front panel push buttons for modifying alarm values and
indicator set-up. Two external inputs for disabling the front panel and
controlling programmable functions.
4. INPUT RANGE: 0.000 to 5.300 A AC @ 25 to 400 Hz.
5. INPUT RESISTANCE: 0.02 W ; 2 W.
6. MAXIMUM SHUNT CURRENT: 50 A for 1 second;
10 AMPS continuous.
Caution: In circuits where fault currents can exceed the maximum shunt
current, a fast blow fuse should be installed in series with the input signal.
Otherwise, a slow blow 10 amp fuse is recommended which will allow for
start-up over current situations, while still protecting the instrument.
7. ACCURACY: (23°C, 85% R.H.)(45-500 Hz) ±(0.5% of reading +5 digits)
8. RESOLUTION: 1 mA
DIMENSIONS In inches (mm)
9. PROGRAMMABLE DISPLAY READING RANGE:
-99999 to 999999.
10. SIGNAL CONNECTION: 2-Wire
11. READING RATE: 2.5 readings/second.
12. RESPONSE TIME: 2 seconds to settle for step input (increases with
programmable digital filtering).
13. TOTALIZER: Front panel button for input/total display select.
Programmable time-base, scale factor (0.001 to 100.000) and low-end cutout.
Max. Response Time = 0.2 seconds.
14. E1-CON & E2-CON: External remote inputs that allow activation of
various functions (reset total, peak indicator mode, trigger mode, etc). V
0.8 V
MAX
15. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0° to 50°C
Storage Temperature: -40° to 80°C
Temperature Coefficient: +/- 200 ppm/°C
Operating and Storage Humidity: 85% max. relative humidity
(non-condensing) from 0°C to 50°C.
Altitude: Up to 2,000 meters
Note: Recommended minimum clearance (behind the panel) for
mounting clip installation is 2.1" (53.3)H x 5.5" (140)W.
-31-
; V
= 2.0 V
; Max Response Time = 0.2 seconds.
IH
MIN
=
IL
PANEL CUT-OUT

Advertisement

Table of Contents
loading