Ordering Information; Specifications - red lion CUB 5TC-K Manual

Miniature electronic 5-digit thermocouple meter
Table of Contents

Advertisement

o
rderinG
TYPE
CUB5
Optional Plug-in Cards
Accessories
Software
1
System requirements for the software are listed on the download page.
G
M
eneral
1. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits
CUB5TCR0: Reflective LCD with full viewing angle
CUB5TCB0: Transmissive LCD with selectable red or green LED backlight,
viewing angle optimized. Display color change capability with output state
when using an output module.
2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input
polarity protection. Must use an RLC model MLPS or an NEC Class 2 or
Limited Power Source (LPS) rated power supply.
MODEL
DISPLAY COLOR
NO.
CUB5TCR0
---
CUB5TCB0
Red (max intensity)
CUB5TCB0
Green (max intensity)
3. READOUT:
Resolution: 1 or 0.1 degrees
Scale: °F or °C
Offset Range: -999 to 9999 display units
4. THERMOCOUPLE INPUTS:
Isolation: TC+ and TC- terminals are not electrically isolated from the power
supply or optional comms cards.
Note: Non-grounded (isolated) thermocouple probes must be used when
the DC power supply's common is not at ground potential, or
measurement errors will occur.
Open Sensor Display:

Overrange/Underrange Input:
ACCURACY
TC TYPE
RANGE
@ 23°C
±°C
-200 to 400°C
T
2.3
-328 to 752°F
-200 to 871°C
E
2.7
-328 to 1600°F
-200 to 760°C
J
1.9
-328 to 1400°F
-200 to 1372°C
K
2.3
-328 to 2502°F
-50 to 1768°C
R
4.5
-58 to 3214°F
-50 to 1768°C
S
4.5
-58 to 3214°F
200 to 1820°C
9.1<540
B
392 to 3308°F
4.5>540
-200 to 1300°C
N
2.8
-328 to 2372°F
mV
-10.00 to 65.00
0.02 mV
Overrange/Underrange Display : "
Maximum Input Voltage: 30 VDC, TC+ to TC-
Maximum Input Voltage TC-: 3 VDC max. with respect to common
*After 20 min. warm-up. Accuracy is specified in two ways: Accuracy at 23°C
and 15 to 75% RH environment; and Accuracy over a -35 to 75°C and 0 to
85% RH (non condensing) environment. Accuracy specified over the -35 to
75°C operating range includes meter tempco and cold junction tracking
i
nforMation
MODEL NO.
DESCRIPTION
Thermocouple Meter with Reflective Display
CUB5TC
Thermocouple Meter with Backlight Display
CUB5RLY
Single Relay Option Card
CUB5SNK
Dual Sinking Open Collector Output card
RS485 Serial Communications Card
CUB5COM
RS232 Serial Communications Card
CUB5USB
USB Programming Card
+12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out
MLPS
+24 VDC Micro-Line Power Supply, 85 to 250 VAC source, 200 mA max out
CBLPROG
Programming Cable RS232 (RJ11-DB9)
CBPRO
Communication Cable RS485 (RJ11-DB9)
CBLUSB
USB Programming Cable
Crimson PC Configuration Software, Free Download from www.redlion.net
S
eter
pecificationS
INPUT CURRENT
INPUT CURRENT
@ 9 VDC WITHOUT
@ 9 VDC WITH
CUB5RLY0
CUB5RLY0
10 mA
40 mA
85 mA
115 mA
95 mA
125 mA
/
ACCURACY
WIRE COLOR
@ -35 to 75°C
ANSI
BS 1843
±°C
(+) blue
(+) white
5.8
(-) red
(-) blue
(+) purple
(+) brown
4.9
(-) red
(-) blue
(+) white
(+) yellow
4.3
(-) red
(-) blue
(+) yellow
(+) brown
5.8
(-) red
(-) blue
no
(+) white
15.0
standard
(-) blue
no
(+) white
15.0
standard
(-) blue
C
42.6<540
C
no
no
°
°
C
15.0>540
C
standard
standard
°
°
(+) orange
(+) orange
8.1
(-) red
(-) blue
no
no
0.08 mV
standard
standard
.....
.....
"/"-
"
effects. The specification includes the A/D conversion errors, linearization
conformity, and thermocouple cold junction compensation. Total system
accuracy is the sum of meter and probe errors. Accuracy may be improved by
field calibrating the meter readout at the temperature of interest.
5. RESPONSE TIME:
Display: 500 msec min.
Output: 800 msec max (with input filter setting of 0)
6. USER INPUT (USR): Programmable input. Connect terminal to common
(USR COMM) to activate function. Internal 10KΩ pull-up resistor to +9 to
28 VDC.
Threshold Levels: V
= 0.7 V max; V
IL
Response Time: 5 msec typ.; 50 msec debounce (activation and release)
7. CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A
Safety requirements for electrical equipment for measurement, control, and
laboratory use:
EN 61010-1: General Requirements
EN 61010-2-030: Particular Requirements for Testing and Measuring
Circuits
RoHS Compliant
UL Recognized Component: File #E179259
UL Listed: File #E137808
Type 4X Indoor/Outdoor Enclosure rating (Face only)
IP65 Enclosure rating (Face only)
IP20 Enclosure rating (Rear of unit)
Refer to EMC Installation Guidelines for additional information.
8. MEMORY: Nonvolatile E
2
parameters and max/min values when power is removed.
9. CONNECTIONS: Wire clamping screw terminals
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 3.5 inch-lbs (0.395 N-m) max.
10. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5TCR0: -35 to 75°C
Operating Temperature Range for CUB5TCB0 depends on display color
and intensity level as per below:
INTENSITY LEVEL
Red Display
1 & 2
Green Display
1 & 2
Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative humidity (non-
condensing)
Vibration to IEC 68-2-6: Operational 5-500 Hz, 5 g
Shock to IEC 68-2-27: Operational 30 g
Altitude: Up to 2000 meters
2
PART NUMBER
CUB5TCR0
CUB5TCB0
CUB5RLY0
CUB5SNK0
CUB5COM1
CUB5COM2
CUB5USB0
MLPS1000
MLPS2000
CBLPROG0
CBPRO007
CBLUSB00
1
= 2.4 V min; V
IH
MAX
PROM memory retains all programming
TEMPERATURE
-35 to 75°C
3
-35 to 70°C
4
-35 to 60°C
5
-35 to 50°C
-35 to 75°C
3
-35 to 65°C
4
-35 to 50°C
5
-35 to 35°C
= 28 VDC

Advertisement

Table of Contents
loading

Table of Contents