Ordering Information; General Meter Specifications - red lion CUB5V Manual

Miniature electronic 5-digit dc voltmeter
Hide thumbs Also See for CUB5V:
Table of Contents

Advertisement

O
RDERING
TYPE
CUB5
Optional Plug-in Cards
Accessories
1
Crimson software is a free download from http://www.redlion.net/
G
ENERAL
1. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits
CUB5VR00: Reflective LCD with full viewing angle
CUB5VB00: Transmissive LCD with selectable red or green LED backlight,
viewing angle optimized. Display color change capability with output state
when using an output module.
2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input
polarity protection.
MODEL
DISPLAY COLOR
NO.
CUB5VR00
CUB5VB00
Red (max intensity)
CUB5VB00
Green (max intensity)
3. INPUT RANGES: Jumper Selectable
D.C. Voltages: 200 mV, 2 V, 20 V, 200 V
4. SIGNAL INPUTS:
ACCURACY
INPUT
@23 °C, less
RANGE
than 85% RH
200 mVDC
0.1% of span 1.027 M
2 VDC
0.1% of span 1.027 M
20 VDC
0.1% of span 1.027 M
200 VDC 0.1% of span 1.027 M
5. OVERRANGE RATINGS, PROTECTION & INDICATION:
9 to 28 VDC power circuit is not isolated from the signal circuit.
Input Overrange Indication: "
Input Underrange Indication: "
Display Overrange/Underrange Indication: "
6. A/D CONVERTER: 16 bit resolution
7. RESPONSE TIME:
Display: 500 msec min.
Output: 800 msec max (with input filter setting of 0)
8. NORMAL MODE REJECTION: 60 dB 50/60 Hz
9. USER INPUT (USR): Programmable input. Connect terminal to common
(USR COMM) to activate function. Internal 10K pull-up resistor to +9 to
28 VDC.
Threshold Levels: V
IL
Response Time: 5 msec typ.; 50 msec debounce (activation and release)
10. CONNECTIONS: Wire clamping screw terminals
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 5 inch-lbs (0.565 N-m) max.
11. MEMORY: Nonvolatile E
parameters and max/min values when power is removed.
12. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for
outdoor use. Installation Category I, Pollution Degree 2. High impact plastic
case with clear viewing window. Panel gasket and mounting clip included.
13. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5VR00: -35 to 75°C
Operating Temperature Range for CUB5VB00 depends on display color
and intensity level as per below:
INTENSITY LEVEL
Red Display
Downloaded from
Elcodis.com
electronic components distributor
I
NFORMATION
MODEL NO.
DESCRIPTION
DC Volt Meter with reflective display
CUB5V
DC Volt Meter with backlight display
CUB5RLY
Single Relay Option Card
CUB5SNK
Dual Sinking Open Collector Output card
RS485 Serial Communications Card
CUB5COM
RS232 Serial Communications Card
CUB5USB
USB Programming Card
+12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out
MLPS
+24 VDC Micro-Line Power Supply, 85 to 250 VAC source, 200 mA max out
CBLPRO
Programming Cable RS232 (RJ11-DB9)
CBPRO
Programming Cable RS485 (RJ11-DB9)
SFCRD
Crimson 2 PC Configuration Software for Windows 98, ME, 2000, XP
CBLUSB
USB Programming Cable
M
S
ETER
PECIFICATIONS
INPUT CURRENT
INPUT CURRENT
@ 9 VDC WITHOUT
CUB5RLY0
---
10 mA
85 mA
95 mA
MAX
INPUT
INPUT
RESOLUTION
IMPEDANCE
SIGNAL
75 VDC
10 μV
75 VDC
.1 mV
250 VDC
1 mV
250 VDC
10 mV
OLOL
".
ULUL
".
.....
.....
"/"-
"
= 1.0 V max; V
= 2.4 V min; V
IH
MAX
2
PROM memory retains all programming
TEMPERATURE
1 & 2
-35 to 75°C
3
-35 to 70°C
4
-35 to 60°C
5
-35 to 50°C
Green Display
Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative humidity (non-
condensing)
@ 9 VDC WITH
Vibration According to IEC 68-2-6: Operational 5 to 500 Hz, in X, Y, Z
CUB5RLY0
direction for 1.5 hours, 5 g's.
40 mA
Shock According to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions.
115 mA
Altitude: Up to 2000 meters
125 mA
14. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Recognized Component, File #E179259, UL61010-1, CSA C22.2 No.
61010-1
Recognized to U.S. and Canadian requirements under the Component
TEMP.
Recognition Program of Underwriters Laboratories, Inc.
COEFFICIENT
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
70 ppm / °C
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
70 ppm / °C
Type 4X Outdoor Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report #E179259-V01-S02
70 ppm / °C
Issued by Underwriters Laboratories, Inc.
70 ppm / °C
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Control and Laboratory use.
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
= 28 VDC
Surge
RF conducted interference
Power frequency magnetic fields
Emissions:
Emissions
Notes:
1. Criterion A: Normal operation within specified limits.
15. WEIGHT: 3.2 oz (100 g)
2
PART NUMBER
CUB5VR00
CUB5VB00
CUB5RLY0
CUB5SNK0
CUB5COM1
CUB5COM2
CUB5USB0
MLPS1000
MLPS2000
CBLPROG0
CBPRO007
1
SFCRD200
CBLUSB00
INTENSITY LEVEL
TEMPERATURE
1 & 2
-35 to 75°C
3
-35 to 65°C
4
-35 to 50°C
5
-35 to 35°C
EN 61000-4-2
Criterion A
4 kV contact discharge
8 kV air discharge
EN 61000-4-3
Criterion A
10 V/m
EN 61000-4-4
Criterion A
2 kV power
1 kV signal
EN 61000-4-5
Criterion A
1 kV L-L,
2 kV L&N-E power
EN 61000-4-6
Criterion A
3 V/rms
EN 61000-4-8
Criterion A
30 A/m
EN 55011
Class A

Advertisement