Preventative Maintenance; Cleaning; Table 3-3: Preventative Maintenance - Aerotech UFM-ST Hardware Manual

Hide thumbs Also See for UFM-ST:
Table of Contents

Advertisement

UFM-ST Hardware Manual

3.4. Preventative Maintenance

While the UFM-ST filter normally does not require any maintenance it is recommended that the filter and
associated wiring be inspected at least once a year.
be made during these inspections.
Table 3-3:
Preventative Maintenance
Check
Visually check filter for loose or damaged
parts / hardware.
Note: Internal inspection is not required
unless internal contamination or damage is
suspected.
Check for fluids or electrically conductive
material on or around filter.
Visually inspect all wires and connectors.
D A N G E R : To minimize the possibility of electrical shock and bodily injury or death,
disconnect power (Mains disconnect) before servicing equipment.
D A N G E R : Always disconnect the Mains power connection before opening the UFM-ST
chassis.

3.4.1. Cleaning

The UFM-ST filter box can be wiped with a clean, dry, soft cloth. The cloth may be slightly moistened if
required with water or isopropyl alcohol to aid in cleaning if necessary. In this case, be careful not to allow
moisture to enter the filter or onto exposed connectors / components. Fluids and sprays are not
recommended because of the possibility of internal contamination, which may result in electrical shorts
and/or corrosion. The electrical power must be disconnected from the filter while cleaning. Do not allow
cleaning substances or other fluids to enter the filter or to get on to any of the connectors. Avoid cleaning the
labels to prevent removing the label information.
D A N G E R : To minimize the possibility of electrical shock and bodily injury or death,
disconnect power (Mains disconnect) before servicing equipment.
20
Table 3-3
lists some recommended checks that should
Action To Be Taken
Parts and hardware should be repaired or replaced.
Remove and cleanup any fluids or conductive Material from
filter. Fluids and conductive material must not be allowed to
enter filter.
Tighten or re-secure any loose connections. Replace or
repair damaged or frayed wires.
Chapter 3
Maintenance
www.aerotech.com