3.1. Troubleshooting

This section lists some symptoms and causes for problems that may be encountered with the UFM-ST filter.
Table 3-1:
Troubleshooting
Symptom
No voltage output
UFM-ST filter blows
fuses
Fails Hi-pot test
D A N G E R : To minimize the possibility of electrical shock and bodily injury or death,
disconnect power (Mains disconnect) before servicing equipment.
www.aerotech.com
Possible Cause and Solution
1. Verify AC input voltage is present at AC1 & AC2.
2. Check for blown fuse inside UFM-ST filter. Fuse can be checked by making
continuity check between Input & Output connectors. Resistance between AC
inputs and outputs is less than 1 OHM. There should be no continuity between
AC1, AC2, and Ground.
1. Check UFM-ST output wiring for shorts.
2. Verify that UFM-ST load is not exceeding 10 Amps.
The UFM-ST filter contains MOV's that will cause a Hi-pot failure and could be
damaged by Hi-pot testing. Contact Aerotech concerning Hi-pot testing the
UFM-ST filter.