3.1. Preventative Maintenance

While the UFM-ST filter normally does not require any maintenance it is recommended that the filter
and associated wiring be inspected at least once a year.
that should be made during these inspections.
Table 3-2:
Preventative Maintenance
Check
Visually check filter for loose or damaged parts
/ hardware.
Note: Internal inspection is not required unless
internal contamination or damage is suspected.
Check for fluids or electrically conductive
material on or around filter.
Visually inspect all wires and connectors.
Cleaning
DANGER: Before you clean the UFM-ST, disconnect the electrical power from the drive.
Use a clean, dry, soft cloth to clean the UFM-ST. If necessary, use a cloth that is moist with water or
isopropyl alcohol. If you use a moist cloth, make sure that moisture does not go into the filter
module. Also make sure that it does not go onto the outer connectors and components. Internal
contamination from the cleaning solution can cause corrosion and electrical short circuits.
Do not clean the labels with a cleaning solution because it might remove the label information.
22
Table 3-2
lists some recommended checks
Action to be Taken
Parts and hardware should be repaired or
replaced.
Remove and cleanup any fluids or conductive
Material from filter. Fluids and conductive
material must not be allowed to enter filter.
Tighten or re-secure any loose connections.
Replace or repair damaged or frayed wires.
Hardware Manual