Environmental Specifications - Aerotech UFM-ST Hardware Manual

Hide thumbs Also See for UFM-ST:
Table of Contents

Advertisement

Introduction

1.2. Environmental Specifications

The environmental specifications for the UFM-ST are listed below.
Ambient Temperature
Convection Cooling
Forced-Air Cooling
Humidity
Altitude
Pollution
Use
www.aerotech.com
Operating: 5° to 40°C (41° to 104° F)
Storage: -20° to 70°C (-4° to 158° F)
Convection cooling can be used for operating currents up to 8 A
Forced-air cooling of 50 LFM at 10 CFM is required for operating currents
above 8 A
rms
Maximum relative humidity is 80% for temperatures up to 31°C.
Decreasing linearly to 50% relative humidity at 40°C. Non condensing.
Up to 2000 meters.
Pollution degree 2 (normally only non-conductive pollution).
Indoor use only.
Chapter 1
UFM-ST Hardware Manual
rms
11

Advertisement

Table of Contents
loading