Initializing The Arisense System - A.R.I. D-040 L ARISENSE Installation Operation & Maintenance

Combination air valve
Table of Contents

Advertisement

9
IOM D-040 L ARISENSE

3. INITIALIZING THE ARISENSE SYSTEM

Once the air valve is physically installed, the Arisense system should be prepared for operation. Please follow the
following steps:
Please note: In cramped installation spaces you may disconnect the
physically installing the valve on the pipeline.
Important: Before performing any work on the air valve, make sure that all workers on site are familiar with the
safety instructions chapter of this document and with all the relevant local and general safety instructions, standards
and work regulations.
3.1. Required tools and materials:
Flat-tip screwdriver
Phillips head screwdriver
8mm combination spanner
6mm Allen key
Plastic head hammer
4.5mm roll pin punch
Small bowl with kitchen type liquid soap
3.2. Open the battery compartment
Using the Phillips head screwdriver, unscrew [1], [2], and remove [3] the two bolts connecting the ARISENSE black Air
Release Outlet.
1
Leak Detector Case from the air valve before
2
3

Advertisement

Table of Contents
loading

Table of Contents