Gain
5
5
5
10
10
10
20
20
20
50
50
50
100
100
100
200
200
200
250
250
250
500
500
500
1000
1000
1000
2000
© National Instruments Corporation
Table 12. SCXI-1121 Test Limits (Continued)
Test Point (V)
Limit (V)
0.9000
4.534293
0.0000
0.005142
–0.9000
–4.465707
0.4500
4.534387
0.0000
0.005236
–0.4500
–4.465613
0.2250
4.534456
0.0000
0.005305
–0.2250
–4.465544
0.0900
4.534694
0.0000
0.005543
–0.0900
–4.465306
0.0450
4.535095
0.0000
0.005944
–0.0450
–4.464905
0.0225
4.535892
0.0000
0.006741
0.0225
–4.464108
0.0180
4.536294
0.0000
0.007143
–0.0180
–4.463706
0.0090
4.538303
0.0000
0.009152
–0.0090
–4.461698
0.0045
4.542321
0.0000
0.013170
–0.0045
–4.457679
0.00225
4.551389
4 Hz Filter Setting
Upper
Lower
Limit (V)
4.465707
–0.005142
–4.534293
4.465613
–0.005236
–4.534387
4.465544
–0.005305
–4.534456
4.465306
–0.005543
–4.534694
4.464905
–0.005944
–4.535095
4.464108
–0.006741
–4.535892
4.463706
–0.007143
–4.536294
4.461698
–0.009152
–4.538303
4.457679
–0.013170
–4.542321
4.448611
17
10 kHz Filter Setting
Upper
Lower
Limit (V)
Limit (V)
4.535706
4.464294
0.006555
–0.006555
–4.464294
–4.535706
4.535771
4.464229
0.006620
–0.006620
–4.464229
–4.535771
4.535979
4.464021
0.006828
–0.006828
–4.464021
–4.535979
4.536146
4.463854
0.006995
–0.006995
–4.463854
–4.536146
4.536551
4.463449
0.007400
–0.007400
–4.463449
–4.536551
4.537797
4.462203
0.008646
–0.008646
–4.462203
–4.537797
4.538614
4.461387
0.009463
–0.009463
–4.461387
–4.538614
4.540951
4.459049
0.011800
–0.011800
–4.459049
–4.540951
4.546501
4.453499
0.017350
–0.017350
–4.453499
–4.546501
4.558631
4.441369
SCXI-1121 Calibration Procedure