Brother BAS-311H Service Manual page 45

Programmable electronic pattern sewer
Hide thumbs Also See for BAS-311H:
Table of Contents

Advertisement

6
X-scale
Parallel movement mode
7
8
Confirm the movement amount
9
Exit parallel movement mode
NOTE:
If you change the program number, the X-scale or the Y-scale, the movement amount which has been stored will be reset.
However, if memory switch No. 465 is set to "3", the movement amount will remain stored and not be reset.
When the power switch is turned off, the movement amount which has been stored will be reset. However, if memory
switch No. 465 is set to "2" or "3", the movement amount will remain stored and will not be reset.
If memory switch No. 465 is set to "3", the movement amount can be set for each program using parameters.
The "Movement amount setting" parameter selection comes in between "Sewing speed" and "Counter".
Y-scale
Parallel movement mode
For example, set to
- 0.05.
TEST indicator switches off
4. X AND Y PARALLEL MOVEMENT OF SEWING PATTERNS
Press the SELECT key so that the Y-SCALE indicator
flashes.
*
When the SELECT key is pressed, the X-SCALE
indicator and the Y-SCALE indicator will flash
alternately.
2649B
Each time the ▲ or ▼ key is pressed, the work clamp will
move by 0.05 mm.
In Y-scale parallel movement mode, the work clamp
will move forward when the ▲ key is pressed, and
backward when the ▼ key is pressed.
The movement units change in accordance with the
movement distance.
0 - 9.95 mm : Increments of 0.05 mm
10.0 - 100 mm : Increments of 0.1 mm
3206B
Press the ENTER key.
The amount of parallel movement in the vertical
direction will be confirmed, and the menu display will
change to illuminated.
2414B
Press the TEST key.
The display will return to the normal display and the
sewing machine will change to home position standby.
*
If you would like to return to step 4, press the SELECT
key instead of the TEST key.
BAS-311H
2401B
2404B
36