I N S T A L L A T I O N I N S T R U C T I O N S
Installation should only be attempted by a qualified installer so that the installation and
maintenance procedures may be followed in the most professional and expert manner possible.
I M P O R TA N T:
Unplug the electrical connection before performing any maintenance or regulation upkeep work.
P O S I T I O N I N G F O R G A S H O B
I M P O R TA N T:
This unit may be installed and used only in permanently ventilated rooms according to British
standards.
The following requirements must be observed:
› The room must be fitted with a ventilation system which vents smoke and gases from
combustion to the outside. This must be done by means of a hood or electric ventilator that
turns on automatically each time the hood is operated.
› The room must also allow for the influx of the air needed for proper combustion. The flow of
air for combustion purposes must, not be less than 2m³/h per kW of installed capacity. The
supply of said air can be effected by means of direct influx from the outside through a duct
with an inner cross section of at least 100cm² which must not be able to be accidentally
blocked.
› Intensive and prolonged use of the appliance may necessitate supplemental ventilation, e.g.
opening a window or increasing the power of the air intake system (if present).