Abrupt braking of the motor, renewed ramping up

Control bits
Bit 1
Bit 0
f
setpoint
Brake
Figure 5-4
The frequency converter is switched off immediately. The motor is stopped by the
external brake. If there isn't an external brake, the motor will stop of its own
accord.
The AUS2 command has a higher priority than AUS1 and AUS3. In other words, a
normal ramp down or an abrupt stop is canceled by AUS2.
If AUS2 is used together with a brake, overload or overvoltage diagnoses may be
obtained.
EM 148-FC Frequency Converter
A5E00065321-03
AUS2
1
0
1
0
f
f
max
0
1
0
Abrupt braking of the motor, renewed ramping up
Mode of Functioning
AUS1
t
t
5-5