LUTControl
This function allows you to apply the
● Registers
Register
Visibility
LUTEnable
Expert
LUTIndex
Expert
LUTValue
Expert
● Setting
- Set the activation of LUT
Set the following value to "LUTEnable" register. The setting value is Boolean type.
- Set the input/output value of LUT
Set the following value to "LUTIndex", "LUTValue" registers. These setting values are Integer type.
"LUTIndex" register value is input level of LUT, and "LUTValue" register value is output level of LUT.
Copyright © 2015 - 2019 Toshiba Teli Corporation, All rights reserved.
LUT(input: 10bit, output: 10bit) to the output images.
arbitrary
Output
luminance
example of LUT setting
Access
R/W
Sets the activation of LUT function.
R/W
Sets the input level of LUT.
R/W
Sets the output level of LUT.
setting value
FALSE (*)
TRUE
LUTIndex / LUTValue
Minimum (*)
Maximum
62 / 74
Binarization
Input
luminance
Description
function
Inactive
Active
* initial factory setting
setting value
0
1023
* initial factory setting
D4245116F
http://www.toshiba-teli.co.jp/en/