4
Inverter assembly
1. Detachment
2. Attachment
Carry out installation by following the dismantling
procedure in reverse (6)
Before pushing the lower part in, pull the reactor leads
out. Take care so that the wiring does not get caught
in the way.
Reconnect all the wiring.
W
o
k r
p
o r
c
e
d
WARNING
Wear a pair of gloves.
Otherwise, you will risk an injury involving
a replacement part or some other object.
1) Stop the air conditioner operation, and turn off the
circuit breaker.
2) Remove the inverter cover.
(M4 × 10, 2 pcs.)
3) Remove the wiring.
(e.g. the power supply wire, compressor leads,
fan motor leads, coils, sensors and heaters)
4) Remove the screws securing the box.
(M5 × 10, 1 pc. each for top and bottom)
5) Disengage the hook by gently pressing down the
locking lever.
(The lower part of the box moves forward.)
6) Hold the top board with both hands to disengage
the top hook.
1)).
u
e r
3)Fanmotor leads
5)Locking lever
When pushing lower part in, be sure to keep
wiring out of way.
- 210 -
R
e
m
a
k r
s
2) Inverter cover
2) Screws (2 locations)
3)Coils, sensors and heaters wire
4)Screw
3)Compressor
leads
4)Screw with
arrow mark
6) Pull it forward
Pushing the lower